DTC B1805/52 Short in Front Passenger Side Squib Circuit |
DTC B1806/52 Open in Front Passenger Side Squib Circuit |
DTC B1807/52 Short to GND in Front Passenger Side Squib Circuit |
DTC B1808/52 Short to B+ in Front Passenger Side Squib Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1805/52 |
|
|
| B1806/52 |
|
|
| B1807/52 |
|
|
| B1808/52 |
|
|

| 1.CHECK FRONT PASSENGER AIRBAG ASSEMBLY (FRONT PASSENGER SIDE SQUIB) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the front passenger airbag assembly.
Connect the white wire side of SST (resistance 2.1 Ω) to connector "G".
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector "G".
Check that the instrument panel wire No.3 connector (on the front passenger airbag assembly side) is not damaged.
|
| ||||
| OK | |
| 3.CHECK FRONT PASSENGER SIDE SQUIB CIRCUIT |
![]() |
Disconnect the connectors from the center airbag sensor assembly.
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - Body ground | Ignition switch ON | Below 1 V |
| J1-2 (P-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - J1-2 (P-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - Body ground | Always | 1 MΩ or higher |
| J1-2 (P-) - Body ground | Always | 1 MΩ or higher |
Check for short in the circuit.
Release the activation prevention mechanism built into connector "B" (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - J1-2 (P-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the front passenger airbag assembly and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 5.CHECK ENGINE ROOM MAIN WIRE |
![]() |
Restore the released activation prevention mechanism of connector "B" to the original condition.
Disconnect the engine room main wire connector from the instrument panel wire.
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HB3-2 (P+) - Body ground | Ignition switch ON | Below 1 V |
| HB3-4 (P-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HB3-2 (P+) - HB3-4 (P-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HB3-2 (P+) - Body ground | Always | 1 MΩ or higher |
| HB3-4 (P-) - Body ground | Always | 1 MΩ or higher |
Check for short to ground in the circuit.
Release the activation prevention mechanism built into connector "B" (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HB3-2 (P+) - HB3-4 (P-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 6.CHECK INSTRUMENT PANEL WIRE |
![]() |
Disconnect the instrument panel wire connector from the instrument panel wire No.3.
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HJ1-2 (P+) - Body ground | Ignition switch ON | Below 1 V |
| HJ1-1 (P-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HJ1-2 (P+) - HJ1-1 (P-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HJ1-2 (P+) - Body ground | Always | 1 MΩ or higher |
| HJ1-1 (P-) - Body ground | Always | 1 MΩ or higher |
Check for short in the circuit.
Release the activation prevention mechanism built into connector "D" (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| HJ1-2 (P+) - HJ1-1 (P-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 7.CHECK INSTRUMENT PANEL WIRE NO.3 |
![]() |
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - Body ground | Ignition switch ON | Below 1 V |
| J1-2 (P-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - J1-2 (P-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - Body ground | Always | 1 MΩ or higher |
| J1-2 (P-) - Body ground | Always | 1 MΩ or higher |
Check for short in the circuit.
Release the activation prevention mechanism built into connector "F" (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| J1-1 (P+) - J1-2 (P-) | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||