2014-2019 Hiace · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Jan 2015

Versions by build date: Oct 2014 – Dec 2014 from Jan 2015


INSPECT OXYGEN SENSOR

  1. A310243E02
    w/o Dual VVT-i:
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance (w/ Secondary Air Injection System):
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher

    Standard Resistance (w/o Secondary Air Injection System):
    Tester Connection
    Condition
    Specified Condition
    1 (HT1A) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1A) - 4 (E2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *A
    w/ Secondary Air Injection System
    *B
    w/o Secondary Air Injection System
    *a
    Component without harness connected
    (Oxygen Sensor)
    If the result is not as specified, replace the oxygen sensor.

  1. A310243E03
    w/ Dual VVT-i:
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    5.9 to 7.3 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Oxygen Sensor)
    If the result is not as specified, replace the oxygen sensor.