2014-2019 Hiace · Service Manual ENGINE

Starter Signal Circuit

Circuit diagnosis · Vehicles built from Jan 2017

Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017

DESCRIPTION

While the engine is being cranked, current flows from terminal ST2 of the ignition switch to the park/neutral position switch and also flows to terminal STA of the ECM (STA Signal).

WIRING DIAGRAM

Refer to DTC P0617 (Click here).

INSPECTION PROCEDURE

NOTICE:
  1. Inspect the fuses of circuits related to this system before performing the following inspection procedure.
  2. After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).

HINT:
This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table (Click here).


1. READ VALUE USING GTS (STARTER SIGNAL)
  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.

  1. Read the value.

    OK:
    Ignition Switch Condition
    Starter Signal
    ON
    OFF
    START
    ON
    Result 
    Result
    Proceed to
    OK
    A
    NG (for A/T)
    B
    NG (for M/T)
    C



B
Go to step 2

C
Go to step 5
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

2. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
  1. Inspect the park/neutral position switch assembly (Click here).



NG
REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH ASSEMBLY - ECM, IGNITION SWITCH)
  1. Disconnect the ignition switch connector.

  1. Disconnect the ECM connector.

  1. Disconnect the park/neutral position switch connector.

  1. Remove the starter (ST) relay from the instrument panel relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H25-1 (ST1) - D37-4
    Always
    Below 1 Ω
    B88-36 (STA) - D37-5
    Always
    Below 1 Ω
    H25-1 (ST1) or D37-4 - Body ground
    Always
    10 kΩ or higher
    B88-36 (STA) or D37-5 - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ignition switch connector.

  1. Reconnect the ECM connector.

  1. Reconnect the park/neutral position switch connector.

  1. Reinstall the starter relay (ST).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4. INSPECT IGNITION SWITCH ASSEMBLY
  1. Inspect the ignition switch (Click here).



NG
REPLACE IGNITION SWITCH ASSEMBLY
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

5. CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - ECM)
  1. Remove the starter (ST) relay from the instrument panel relay block.

  1. Disconnect the ECM connector.

  1. Disconnect the ignition switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H25-1 (ST1) - B88-36 (STA)
    Always
    Below 1 Ω
    H25-1 (ST1) or B88-36 (STA) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the starter relay (ST).

  1. Reconnect the ECM connector.

  1. Reconnect the ignition switch connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6. INSPECT IGNITION SWITCH ASSEMBLY
  1. Inspect the ignition switch (Click here).



NG
REPLACE IGNITION ASSEMBLY
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR


← Starter Signal Circuit (Apr 2016 – Dec 2016)Injector Circuit (Oct 2014 – Dec 2014) →