INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT RESISTANCE |
 |
- Measure the resistance according to the value(s) in the table below.
- Resistance:
Terminal No (Terminal mark)
|
Oil temperature
|
Resistance
|
1(OT+)←→5(OT-)
|
10°C (50°F)
|
6.4 kΩ
|
1(OT+)←→5(OT-)
|
110°C (230°F)
|
0.2 kΩ
|