2014-2019 Hiace · Service Manual BODY ELECTRICAL

REMOVAL

Removal / installation · Vehicles built from Jan 2017

Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017


1. REMOVE INSTRUMENT CLUSTER FINISH PANEL GARNISH NO. 2

  1. B102813
    Using a moulding remover D, detach the 3 claws and remove the instrument cluster finish panel garnish No. 2.


2. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY CENTER
  1. for Standard Body:
    Using a moulding remover D, detach the 4 claws in the order shown in the illustration.

  1. for Wide Body:
    Using a moulding remover D, detach the 5 claws in the order shown in the illustration.

    B365537E01

    Text in Illustration 
    *A
    for Standard Body
    *B
    for Wide Body

  1. B366735E01
    Apply protective tape as shown in the illustration.
    Text in Illustration 
    *1
    Protective Tape

  1. Using a moulding remover D, detach the claw.

  1. B365539
    Detach the claw as shown in the illustration.

  1. B102817
    Detach the 3 claws as shown in the illustration.

  1. B102818
    Detach the 2 claws as shown in the illustration.

  1. for Standard Body:
    Detach the 3 claws and remove the instrument cluster finish panel sub-assembly center.

  1. for Wide Body:
    Detach the 4 claws and remove the instrument cluster finish panel sub-assembly center.

    B365540E01

    Text in Illustration 
    *A
    for Standard Body
    *B
    for Wide Body


3. REMOVE INSTRUMENT CLUSTER FINISH PANEL GARNISH NO. 1

  1. B365541
    Using a moulding remover D, detach the 3 claws and remove the instrument cluster finish panel garnish No. 1.


4. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY

  1. B365542
    Using a moulding remover D, detach the 4 claws and remove the instrument cluster finish panel assembly.


5. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY

  1. B365543
    Detach the 6 claws and 4 hooks and remove the instrument cluster finish panel sub-assembly.


6. REMOVE COMBINATION METER ASSEMBLY

  1. B366842
    Remove the 2 screws.

  1. B366843
    Detach the 2 claws and remove the combination meter assembly.

  1. Disconnect the 2 connectors and detach the wire harness clamp.

← REMOVAL (Apr 2016 – Dec 2016)DISASSEMBLY (from Oct 2014) →