P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)
Diagnostic trouble codes · Vehicles built Jan 2015 – Mar 2016
Versions by build date: Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017
DESCRIPTION
Changing from 1st to 6th is performed by the ECM turning shift solenoid valves SL1, SL2, SL3 and SL4 on and off. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated (Click here).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0748 |
An open or short circuit (output signal duty is 0% or 100%) is detected by the ECM in the shift solenoid valve SL1 circuit while driving and shifting gears (SL1 output signal duty is more than 0% and less than 100% under normal conditions) (1 trip detection logic). |
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any of the shift solenoid valve circuits, the ECM detects the problem and illuminates the MIL and stores the DTC. The ECM also performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the ECM stops sending current to the circuit.)While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines there is a malfunction (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Perform registration and/or initialization when parts related to the automatic transmission are replaced (Click here).
- HINT:
- The following table shows normal operation of the shift solenoid valve SL1 when the shift lever is in D:
ECM commanded gear
1st
2nd
3rd
4th
5th
6th
Shift solenoid valve SL1
ON
ON
ON
ON
OFF
OFF
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
Disconnect the transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
25 (SL1+) - 26 (SL1-)
20°C (68°F)
5.0 to 5.6 Ω
25 (SL1+) - Body ground
Always
10 kΩ or higher
26 (SL1-) - Body ground
Always
10 kΩ or higher
Text in Illustration *a
Component without harness connected
(Transmission Wire)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Disconnect the ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D116-11 (SL1+) - D116-10 (SL1-)
20°C (68°F)
5.0 to 5.6 Ω
D116-11 (SL1+) - Body ground
Always
10 kΩ or higher
D116-10 (SL1-) - Body ground
Always
10 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to ECM)
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL1 |
Remove shift solenoid valve SL1 (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 1
| *1 |
Shift Solenoid Valve SL1 |
|
|
||||
| OK | ||
| ||