INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT AIR SWITCHING VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20 °C (68 °F)
4.5 to 5.5 Ω
1 - Body ground
Always
1MΩ or higher
2 - Body ground
- HINT:
- When measuring the resistance make sure that the surface temperature of the air switching valve assembly is 20°C (68 °F).
Check the operation of the air switching valve assembly.
Check that air does not flow from port A to port B.

Text in Illustration *a
Port A
*b
Port B


Air
- NOTICE:
- Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.
Apply battery voltage across terminals 1 and 2.

Text in Illustration *a
Port A
*b
Port B


Air
- NOTICE:
- Apply voltage for 2 minutes or less.
Check that air flows from port A to port B.
If the result is not as specified, replace the air switching valve assembly.