ON-VEHICLE INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT REFRIGERANT VOLUME |
Check the sight glass on the liquid tube sub-assembly A.

Test conditions:- Engine is running at 1,500 rpm.
- Blower speed control switch is at "HI".
- A/C switch is on.
- Temperature control switch is at the "MAX COOL" position.
- Doors are fully open.
*: Bubbles in the sight glass with ambient temperature higher than usual can be considered normal if cooling is sufficient.Item
Symptom
Amount of refrigerant
Corrective Action
1
Bubbles exist
Insufficient*
- Check for gas leakage and repair if necessary
- Add refrigerant until bubbles disappear
2
No bubbles exist
Empty, insufficient or excessive
Refer to 3 and 4
3
No temperature difference between compressor inlet and outlet
Empty or nearly empty
- Check for gas leakage with gas leak detector and repair if necessary
- Add refrigerant until bubbles disappear
4
Considerable temperature difference between compressor inlet and outlet
Proper or excessive
Refer to 5 and 6
5
Immediately after air conditioning is turned off, refrigerant clears
Excessive
- Discharge refrigerant
- Remove air and supply proper amount of purified refrigerant
6
Immediately after air conditioning is turned off, refrigerant foams and then becomes clear
Proper
-
- Engine is running at 1,500 rpm.
| INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
This is a method in which the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when the following conditions are established.
Test conditions:- Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F).
- Engine is running at 1,500 rpm.
- Blower speed control switch is at "HI".
- Temperature control dial is at "COOL".
- A/C switch is on.
- Doors are fully open.
Refrigerant system functions normally.

- Gauge reading:
- Low pressure side:
- 0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21.3 to 35.6 psi)
- High pressure side:
- 1.37 to 1.57MPa (14 to 16 kgf/cm2, 199 to 228 psi)
Moisture present in refrigeration system.


Symptom
Probable cause
Diagnosis
Corrective Action
During operation, pressure on low pressure side cycles between normal and vacuum
Moisture in refrigeration system freezes at expansion valve orifice, causing a temporary stop of cycle. However, when it melts, normal state is restored.
- Drier in oversaturated state
- Moisture in refrigeration system freezes at expansion valve orifice and blocks circulation of refrigerant
- Replace condenser
- Remove moisture in cycle by repeatedly evacuating air
- Supply a proper amount of new refrigerant
- Drier in oversaturated state
Insufficient cooling


System
Probable cause
Diagnosis
Corrective Action
- Pressure is low on both low and high pressure sides
- Bubbles are seen through sight glass continuously
- Insufficient cooling performance
Gas leakage in refrigeration system
- Insufficient refrigerant
- Refrigerant leaking
- Check for gas leakage and repair if necessary
- Supply a proper amount of new refrigerant
- If the indicated pressure value is close to 0 when connected to the gauge, create a vacuum after inspecting and repairing the location of leakage.
- Pressure is low on both low and high pressure sides
Poor circulation of refrigerant


System
Probable cause
Diagnosis
Corrective Action
- Pressure is low on both low and high pressure sides
- Frost exists on pipe from condenser to unit
Refrigerant flow is obstructed by dirt in the receiver
Receiver is clogged
Replace condenser
- Pressure is low on both low and high pressure sides
Refrigerant does not circulate.


System
Probable cause
Diagnosis
Corrective Action
- Vacuum is indicated on low pressure side and very low pressure is indicated on high pressure side
- Frost or condensation is seen on piping on both sides of receiver/drier or expansion valve
- Refrigerant flow is obstructed by moisture or dirt in refrigeration system
- Refrigerant flow is obstructed by gas leak from expansion valve
Refrigerant does not circulate
- Check the expansion valve
- Replace condenser
- Evacuate air and supply a proper amount of new refrigerant
- For gas leakage from expansion valve, replace expansion valve
- Vacuum is indicated on low pressure side and very low pressure is indicated on high pressure side
Refrigerant is overcharged or cooling effectiveness of condenser is insufficient.


System
Probable cause
Diagnosis
Corrective Action
- Pressure is too high on both low and high pressure sides
- No air bubbles are seen through sight glass even when engine rpm lowers
- Unable to develop sufficient performance due to excessive charging of refrigeration system
- Cooling effectiveness of condenser is insufficient.
- Excessive refrigerant in cycle → excessive refrigerant is supplied
- Condenser cooling effectiveness in insufficient → condenser fins are clogged at cooling fan
- Clean condenser
- Check cooling fan with cooling fan motor operated
- If 1. and 2. are normal, check the amount of refrigerant and supply a proper amount of refrigerant
- Pressure is too high on both low and high pressure sides
Air is present in refrigeration system.


System
Probable cause
Diagnosis
Corrective Action
- Pressure is too high on both low and high pressure sides
- The low pressure piping is too hot to touch
- Bubbles can be seen through sight glass
Air in system
- Air present in refrigeration system
- Insufficient purging
- Check compressor oil to see if it is dirty or insufficient
- Vacuum and supply new refrigerant
- Pressure is too high on both low and high pressure sides
Expansion valve malfunction


System
Probable cause
Diagnosis
Corrective Action
- Pressure is too high on both low and high pressure sides
- Frost or a large amount of condensation is on piping on low pressure side
Trouble in expansion valve
- Excessive refrigerant in low pressure piping
- Expansion valve opened too wide
Check expansion valve
- Pressure is too high on both low and high pressure sides
Defective compressor


System
Probable cause
Diagnosis
Corrective Action
- Pressure is too high on both low and high pressure sides
- Pressure is too low on high pressure side
Internal leak in compressor
- Compression failure
- Leakage from damaged valve or broken sliding parts
Repair or replace compressor
- Gauge readings (Reference)


- Pressure is too high on both low and high pressure sides
- Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F).