2014-2019 Hiace · Service Manual HEATER & AIR CONDITIONING SYSTEM

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Oct 2014


INSPECT REFRIGERANT VOLUME

  1. E104574E01
    Check the sight glass on the liquid tube sub-assembly A.
    Test conditions:
    1. Engine is running at 1,500 rpm.
    2. Blower speed control switch is at "HI".
    3. A/C switch is on.
    4. Temperature control switch is at the "MAX COOL" position.
    5. Doors are fully open.
    Item
    Symptom
    Amount of refrigerant
    Corrective Action
    1
    Bubbles exist
    Insufficient*
    1. Check for gas leakage and repair if necessary
    2. Add refrigerant until bubbles disappear
    2
    No bubbles exist
    Empty, insufficient or excessive
    Refer to 3 and 4
    3
    No temperature difference between compressor inlet and outlet
    Empty or nearly empty
    1. Check for gas leakage with gas leak detector and repair if necessary
    2. Add refrigerant until bubbles disappear
    4
    Considerable temperature difference between compressor inlet and outlet
    Proper or excessive
    Refer to 5 and 6
    5
    Immediately after air conditioning is turned off, refrigerant clears
    Excessive
    1. Discharge refrigerant
    2. Remove air and supply proper amount of purified refrigerant
    6
    Immediately after air conditioning is turned off, refrigerant foams and then becomes clear
    Proper
    -
    *: Bubbles in the sight glass with ambient temperature higher than usual can be considered normal if cooling is sufficient.


INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

  1. This is a method in which the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when the following conditions are established.
    Test conditions:

    1. Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F).
    2. Engine is running at 1,500 rpm.
    3. Blower speed control switch is at "HI".
    4. Temperature control dial is at "COOL".
    5. A/C switch is on.
    6. Doors are fully open.

    1. E050573
      Refrigerant system functions normally.

      Gauge reading:
      Low pressure side:
      0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21.3 to 35.6 psi)
      High pressure side:
      1.37 to 1.57MPa (14 to 16 kgf/cm2, 199 to 228 psi)

    2. Moisture present in refrigeration system.

      I022117E06

      Symptom
      Probable cause
      Diagnosis
      Corrective Action
      During operation, pressure on low pressure side cycles between normal and vacuum
      Moisture in refrigeration system freezes at expansion valve orifice, causing a temporary stop of cycle. However, when it melts, normal state is restored.
      1. Drier in oversaturated state
      2. Moisture in refrigeration system freezes at expansion valve orifice and blocks circulation of refrigerant
      1. Replace condenser
      2. Remove moisture in cycle by repeatedly evacuating air
      3. Supply a proper amount of new refrigerant

    3. Insufficient cooling

      I022118E03

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Pressure is low on both low and high pressure sides
      2. Bubbles are seen through sight glass continuously
      3. Insufficient cooling performance
      Gas leakage in refrigeration system
      1. Insufficient refrigerant
      2. Refrigerant leaking
      1. Check for gas leakage and repair if necessary
      2. Supply a proper amount of new refrigerant
      3. If the indicated pressure value is close to 0 when connected to the gauge, create a vacuum after inspecting and repairing the location of leakage.

    4. Poor circulation of refrigerant

      I022119E03

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Pressure is low on both low and high pressure sides
      2. Frost exists on pipe from condenser to unit
      Refrigerant flow is obstructed by dirt in the receiver
      Receiver is clogged
      Replace condenser

    5. Refrigerant does not circulate.

      I022120E02

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Vacuum is indicated on low pressure side and very low pressure is indicated on high pressure side
      2. Frost or condensation is seen on piping on both sides of receiver/drier or expansion valve
      1. Refrigerant flow is obstructed by moisture or dirt in refrigeration system
      2. Refrigerant flow is obstructed by gas leak from expansion valve
      Refrigerant does not circulate
      1. Check the expansion valve
      2. Replace condenser
      3. Evacuate air and supply a proper amount of new refrigerant
      4. For gas leakage from expansion valve, replace expansion valve

    6. Refrigerant is overcharged or cooling effectiveness of condenser is insufficient.

      I022121E04

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Pressure is too high on both low and high pressure sides
      2. No air bubbles are seen through sight glass even when engine rpm lowers
      1. Unable to develop sufficient performance due to excessive charging of refrigeration system
      2. Cooling effectiveness of condenser is insufficient.
      1. Excessive refrigerant in cycle → excessive refrigerant is supplied
      2. Condenser cooling effectiveness in insufficient → condenser fins are clogged at cooling fan
      1. Clean condenser
      2. Check cooling fan with cooling fan motor operated
      3. If 1. and 2. are normal, check the amount of refrigerant and supply a proper amount of refrigerant

    7. Air is present in refrigeration system.

      I022122E07

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Pressure is too high on both low and high pressure sides
      2. The low pressure piping is too hot to touch
      3. Bubbles can be seen through sight glass
      Air in system
      1. Air present in refrigeration system
      2. Insufficient purging
      1. Check compressor oil to see if it is dirty or insufficient
      2. Vacuum and supply new refrigerant

    8. Expansion valve malfunction

      I022123E03

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Pressure is too high on both low and high pressure sides
      2. Frost or a large amount of condensation is on piping on low pressure side
      Trouble in expansion valve
      1. Excessive refrigerant in low pressure piping
      2. Expansion valve opened too wide
      Check expansion valve

    9. Defective compressor

      I022124E03

      System
      Probable cause
      Diagnosis
      Corrective Action
      1. Pressure is too high on both low and high pressure sides
      2. Pressure is too low on high pressure side
      Internal leak in compressor
      1. Compression failure
      2. Leakage from damaged valve or broken sliding parts
      Repair or replace compressor
      1. Gauge readings (Reference)

      I030081E07