Variable Resistor Circuit
Circuit diagnosis · Vehicles built from Oct 2014
DESCRIPTION
The variable resistor is used to adjust the concentration of CO in the exhaust during idling. By turning the idle mixture adjusting screw located on the variable resistor clockwise, the contact inside the resistor is moved and the voltage at the VAF terminal rises accordingly. Conversely, turning the adjusting screw counterclockwise reduces the VAF terminal voltage. When the VAF terminal voltage rises, the ECM increases the fuel injection volume slightly, thus making the air-fuel ratio slightly richer.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Always use a CO meter when adjusting the concentration of CO during idling. If a CO meter is not available, do not attempt to adjust the idling CO concentration.
| 1. CHECK CO/HC |
Make sure the following conditions are met:
All the vacuum lines are properly connected.
The CO meter is properly calibrated.
Start the engine.
Make sure the following conditions are met:
The parking brake is securely applied.
The shift lever is in neutral.
All the accessories are switched off.
Warm up the engine and check that the idling speed is appropriate.
Race the engine at 2500 rpm for approximately 2 minutes.
Insert a tester probe at least 40 cm (1.3 ft.) into the tailpipe.
Measure the CO concentration 1 to 3 minutes after racing the engine to allow the concentration to stabilize.
- Standard CO concentration rate at idling:
- 1.0 to 2.0%
- HINT:
- If the result is outside the standard range shown above, maintain the measurement conditions established during this procedure. The measurement conditions are used in the CO concentration adjustment procedure described below.
|
|
||||
| OK | ||
| ||
| 2. ADJUST CO CONCENTRATION |
Make sure that all the conditions established in the previous procedure remain unchanged.

Regulate the idling CO concentration so that it is within 1.0 to 2.0%.
- HINT:
- Use SST and the idle mixture adjusting screw located on the variable resistor. By turning the adjusting screw, the idling CO concentration rate can be regulated.
Reference Result
Proceed To
Unable to obtain standard concentration rate
A
Standard concentration rate obtained
B
- SST
- 09243-00020
|
|
||||
| A | |
| 3. INSPECT VARIABLE RESISTOR |
Remove the variable resistor.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (E2) - 2 (VC)
Always
3.5 to 6.5 kΩ
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (E2) - 3 (VAF)
Adjusting screw turned fully clockwise
3.5 to 6.5 kΩ
Adjusting screw turned fully counterclockwise
0 kΩ
- SST
- 09243-00020
- HINT:
- When the adjusting screw is turned fully clockwise, the resistance is the same as the measurement value between terminals 1 and 2. When the adjusting screw is turned fully counterclockwise, the resistance changes to 0 kΩ.
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (VARIABLE RESISTOR - ECM) |
Disconnect the variable resistor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D31-2 (VC) - D97-119 (VC)
Always
Below 1 Ω
D31-3 (VAF) - D97-80 (OX1B)
Always
Below 1 Ω
D31-1 (E2) - D97-72 (E2)
Always
Below 1 Ω
D31-2 (VC) or D97-119 (VC) - Body ground
Always
10 kΩ or higher
D31-3 (VAF) or D97-80 (OX1B) - Body ground
Always
10 kΩ or higher
D31-1 (E2) or D97-72 (E2) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 5. INSPECT ECM (VC VOLTAGE) |
Disconnect the variable resistor connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
D31-2 (VC) - D31-1 (E2)
Ignition switch ON
4.5 to 5.5 V
Text in Illustration *a
Front view of wire harness connector
(to Variable Resistor)
|
|
||||
| OK | ||
| ||
