2014-2019 Hiace · Service Manual BODY

TERMINALS OF ECU

System information · Vehicles built Oct 2014 – Nov 2015

Versions by build date: Oct 2014 – Nov 2015 from Dec 2015


CHECK SLIDE DOOR CLOSER RELAY LH (w/o Power Slide Door)

  1. B365267
    Disconnect the slide door closer relay LH connector.

  2. Measure the voltage and resistance according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    7 (GND) - Body ground
    B - Body ground
    Ground
    Slide door LH fully open → fully close
    Below 1 Ω
    5 (+B) - Body ground
    R - Body ground
    Battery power supply
    Slide door LH fully open → fully close
    Below 1 V → 11 to 14 V
    3 (HALF) - 8 (SWE)
    Y - L
    Latch switch condition
    Slide door LH open → halfway position
    Below 1 Ω → 10 kΩ or higher
    4 (FULL) - 8 (SWE)
    B - L
    Latch switch condition
    Slide door LH open → fully close
    Below 1 Ω → 10 kΩ or higher
    9 (PAWL) - 8 (SWE)
    R - L
    Pawl switch condition
    Slide door LH fully close → open
    10 kΩ or higher → Below 1 Ω
    9 (PAWL) - 8 (SWE)
    R - L
    Pawl switch condition
    Slide door LH halfway position
    10 kΩ or higher
    9 (PAWL) - 8 (SWE)
    R - L
    Pawl switch condition
    Slide door LH open → fully close
    10 kΩ or higher → Below 1 Ω

  3. Reconnect the slide door closer relay LH connector.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    1 (DC-) - 7 (GND)
    B - B
    Slide door LH motor normal rotation output
    Slide door LH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    2 (DC+) - 7 (GND)
    R - B
    Slide door LH motor revers rotation output
    Slide door LH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V → Below 1 V
    10 (POS) - 8 (SWE)
    G - L
    Pawl switch condition
    Slide door LH open → halfway position → normal rotation operation → pull the slide door outside handle or inside handle → revers rotation operation → operation stop
    11 to 14 V → 11 to 14 V → 11 to 14 V → Below 1 V → 11 to 14 V


CHECK SLIDE DOOR CLOSER RELAY RH (w/o Power Slide Door)

  1. B365267
    Disconnect the slide door closer relay RH connector.

  2. Measure the voltage and resistance according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    7 (GND) - Body ground
    B - Body ground
    Ground
    Slide door RH fully open → fully close
    Below 1 Ω
    5 (+B) - Body ground
    R - Body ground
    Battery power supply
    Slide door RH fully open → fully close
    Below 1 V → 11 to 14 V
    3 (HALF) - 8 (SWE)
    Y - L
    Latch switch condition
    Slide door RH open → halfway position
    Below 1 Ω → 10 kΩ or higher
    4 (FULL) - 8 (SWE)
    B - L
    Latch switch condition
    Slide door RH open → fully close
    Below 1 Ω → 10 kΩ or higher
    9 (PAWL) - 8 (SWE)
    R - L
    Pawl switch condition
    Slide door RH fully close → open
    10 kΩ or higher → Below 1 Ω
    9 (PAWL) - 8 (SWE)
    R - L
    Pawl switch condition
    Slide door RH halfway position
    10 kΩ or higher
    9 (PAWL) - 8 (SWE)
    R - L
    Pawl switch condition
    Slide door RH open → fully close
    10 kΩ or higher → Below 1 Ω

  3. Reconnect the slide door closer relay RH connector.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    1 (DC-) - 7 (GND)
    B - B
    Slide door RH motor normal rotation output
    Slide door RH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    2 (DC+) - 7 (GND)
    R - B
    Slide door RH motor revers rotation output
    Slide door RH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V → Below 1 V
    10 (POS) - 8 (SWE)
    G - L
    Pawl switch condition
    Slide door RH open → halfway position → normal rotation operation → pull the slide door outside handle or inside handle → revers rotation operation → operation stop
    11 to 14 V → 11 to 14 V → 11 to 14 V → Below 1 V → 11 to 14 V


CHECK DOOR CONTROL RELAY LH (w/o Power Slide Door)

  1. B365269E01
    Disconnect the B32 door control relay LH connector.

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    B32-1 (B) - Body ground
    B-R - Body ground
    Battery power supply
    Always
    11 to 14 V
    B32-3 (E) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω

  3. Reconnect the B32 door control rely LH connector.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    B32-4 (SW) - Body ground
    L - Body ground
    Battery power supply
    Slide door LH open → halfway position
    Below 1 V → 11 to 14 V
    B32-5 (RLY) - Body ground
    G - Body ground
    Battery power supply
    Slide door LH open → halfway position (slide door closer operate) → approximately 18 seconds after the slide door LH halfway position or slide door LH open
    Below 1 V → 11 to 14 V → Below 1 V


CHECK DOOR CONTROL RELAY RH (w/o Power Slide Door)

  1. B365269E02
    Disconnect the M2 door control relay RH connector.

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    M2-1 (ECUB) - Body ground
    B-R - Body ground
    Battery power supply
    Always
    11 to 14 V
    M2-3 (GND) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω

  3. Reconnect the M2 door control rely RH connector.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    M2-4 (FUL) - Body ground
    B - Body ground
    Battery power supply
    Slide door RH open → halfway position
    Below 1 V → 11 to 14 V
    M2-5 (IG) - Body ground
    G - Body ground
    Battery power supply
    Slide door RH open → halfway position (slide door closer operate) → approximately 18 seconds after the slide door RH halfway position or slide door RH open
    Below 1 V → 11 to 14 V → Below 1 V


CHECK DOOR CONTROL RELAY ASSEMBLY (for LH Side [w/ Power Slide Door])

  1. Disconnect the q3 and q4 door control relay assembly connectors.
    B365268E01

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    q3-7 (GND) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    q3-8 (B) - Body ground
    B-R - Body ground
    Battery power supply
    Always
    11 to 14 V
    q4-9 (IG) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch ON
    11 to 14 V
    q4-9 (IG) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch off
    Below 1 V
    q4-11 (ECUB) - Body ground
    W - Body ground
    Battery power supply
    Always
    11 to 14 V
    q4-21 (SEL) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    q4-5 (FUL) - Body ground
    Y - Body ground
    Full latch switch input
    Slide door LH open → fully closed
    Below 1 Ω → 10 kΩ or higher
    q4-4 (HAF) - Body ground
    B - Body ground
    Half latch switch input
    Slide door LH fully open → half latched
    Below 1 Ω → 10 kΩ or higher
    q4-18 (POL) - Body ground
    R - Body ground
    Pawl switch input
    Slide door LH fully closed → half latched (latch pushed slightly toward full latch position)
    10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
    q4-18 (POL) - Body ground
    R - Body ground
    Pawl switch input
    Half latched
    Below 1 Ω
    q4-18 (POL) - Body ground
    R - Body ground
    Pawl switch input
    Slide door LH fully open → half latched (latch pushed slightly toward full latch position)
    10 kΩ or higher → Below 1 Ω → 10 kΩ or higher

  3. Reconnect the q3 and q4 door control relay assembly connectors.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    Q3-1 (DC-) - Body ground
    P - Body ground
    Door closer output
    Slide door LH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    Q3-5 (DC+) - Body ground
    L - Body ground
    Door closer output
    Slide door LH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V → Below 1 V
    Q4-19 (LMT) - Body ground
    W - Body ground
    Initial position switch input
    Slide door LH open → halfway position → normal rotation operation → pull the slide door outside handle or inside handle → revers rotation operation → operation stop
    11 to 14 V → 11 to 14 V → Below 1 V → 11 to 14 V → Below 1 V → 11 to 14 V


CHECK DOOR CONTROL RELAY ASSEMBLY (for RH Side [w/ Power Slide Door])

  1. Disconnect the I3 and I4 door control relay assembly connectors.
    B365268E02

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    I3-7 (GND) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    I3-8 (B) - Body ground
    B-R - Body ground
    Battery power supply
    Always
    11 to 14 V
    I4-9 (PCV1) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch ON
    11 to 14 V
    I4-9 (PCV1) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch off
    Below 1 V
    I4-11 (ECUB) - Body ground
    W - Body ground
    Battery power supply
    Always
    11 to 14 V
    I4-21 (SEL) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    I4-5 (FUL) - Body ground
    Y - Body ground
    Full latch switch input
    Slide door RH open → fully closed
    Below 1 Ω → 10 kΩ or higher
    I4-4 (HAF) - Body ground
    B - Body ground
    Half latch switch input
    Slide door RH fully open → half latched
    Below 1 Ω → 10 kΩ or higher
    I4-18 (POL) - Body ground
    R - Body ground
    Pawl switch input
    Slide door RH fully closed → half latched (latch pushed slightly toward full latch position)
    10 kΩ or higher → Below 1 Ω → 10 kΩ or higher
    I4-18 (POL) - Body ground
    R - Body ground
    Pawl switch input
    Half latched
    Below 1 Ω
    I4-18 (POL) - Body ground
    R - Body ground
    Pawl switch input
    Slide door RH fully open → half latched (latch pushed slightly toward full latch position)
    10 kΩ or higher → Below 1 Ω → 10 kΩ or higher

  3. Reconnect the I3 and I4 door control relay assembly connectors.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    I3-1 (DC-) - Body ground
    P - Body ground
    Door closer output
    Slide door RH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    I3-5 (DC+) - Body ground
    L - Body ground
    Door closer output
    Slide door RH open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V → Below 1 V
    I4-19 (LMT) - Body ground
    W - Body ground
    Initial position switch input
    Slide door RH open → halfway position → normal rotation operation → pull the slide door outside handle or inside handle → revers rotation operation → operation stop
    11 to 14 V → 11 to 14 V → Below 1 V → 11 to 14 V → Below 1 V → 11 to 14 V

← PROBLEM SYMPTOMS TABLE (from Dec 2015)TERMINALS OF ECU (from Dec 2015) →