INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT POWER SLIDE DOOR LOCK ASSEMBLY RH |
Inspect the door closer motor.

Apply battery voltage and check operation of the slide door closer motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Close (Forward)
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Open (Reverse)
Inspect the pawl switch and latch switch

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
- Pawl switch:
Tester Connection
Condition
Specified Condition
8 - 9
- Open
- Half latch
- Full latch
10 kΩ or higher
8 - 9
Unlatched
Below 1 Ω
- Open
- Latch switch:
Tester Connection
Condition
Specified Condition
3 - 4, 4- 8
Open
Below 1 Ω
4 - 8
Half latch
Below 1 Ω
3 - 4, 4- 8
Full latch
10 kΩ or higher
-
Over stroke
10 kΩ or higher
Inspect the initial position switch and handle switch.

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
8 - 10
- Handle switch ON (Handle initial position)
- Initial position switch OFF (Active lever initial position)
10 kΩ or higher
8 - 10
- Handle switch OFF (As handling)
- Initial position switch OFF (Active lever initial position)
10 kΩ or higher
8 - 10
- Handle switch ON (Handle initial position)
- Initial position switch ON (As closer operating)
Below 1 Ω
8 - 10
- Handle switch OFF (As handling)
- Initial position switch ON (As closer operating)
10 kΩ or higher
- Handle switch ON (Handle initial position)
| INSPECT POWER SLIDE DOOR LOCK ASSEMBLY LH |
Inspect the door closer motor.

Apply battery voltage and check operation of the slide door closer motor.
- Standard:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Close (Forward)
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Open (Reverse)
Inspect the pawl switch and latch switch

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
- Pawl switch:
Tester Connection
Condition
Specified Condition
8 - 9
- Open
- Half latch
- Full latch
10 kΩ or higher
8 - 9
Unlatched
Below 1 Ω
- Open
- Latch switch:
Tester Connection
Condition
Specified Condition
3 - 4, 4- 8
Open
Below 1 Ω
4 - 8
Half latch
Below 1 Ω
3 - 4, 4- 8
Full latch
10 kΩ or higher
-
Over stroke
10 kΩ or higher
Inspect the initial position switch and handle switch.

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
8 - 10
- Handle switch ON (Handle initial position)
- Initial position switch OFF (Active lever initial position)
10 kΩ or higher
8 - 10
- Handle switch OFF (As handling)
- Initial position switch OFF (Active lever initial position)
10 kΩ or higher
8 - 10
- Handle switch ON (Handle initial position)
- Initial position switch ON (As closer operating)
Below 1 Ω
8 - 10
- Handle switch OFF (As handling)
- Initial position switch ON (As closer operating)
10 kΩ or higher
- Handle switch ON (Handle initial position)