FAIL-SAFE CHART
System information · Vehicles built from Oct 2014
| Automatic Light Control System (w/ Automatic Light Control System) |
If the frequency output from the automatic light control sensor becomes 30 Hz or less, the body ECU will activate the fail-safe function.
If a problem occurs in the automatic light control system when the headlight dimmer switch is in the AUTO position and the headlights or taillights are on, the body ECU will keep the lights on until the headlight dimmer switch is turned off or the conditions for activating the headlight auto cut system are met.
If a problem occurs in the automatic light control system when the headlight dimmer switch assembly is in the AUTO position, and both headlights and taillights are off, the body ECU will interrupt the automatic light control system operation and keep both headlights and taillights off until the frequency output from the automatic light control sensor is determined to be normal.
| Automatic Headlight Beam Level Control System (for LED Headlight) |
The headlight leveling ECU operates in fail-safe mode if an abnormal condition such as those listed below has been detected.
Item
Abnormality Detection Condition
Return Condition
Warning Display
Height control sensor power source voltage
Abnormal height control sensor power source voltage (4.6 V or less, or 6.25 V or more) is detected.
Voltage of 4.61 to 6.24 V is detected
Displayed
Height control sensor signal voltage
Abnormal height control sensor signal voltage (0.25 V or less, or 4.75 V or more) is detected.
Voltage of 0.26 to 4.74 V is detected
High power source voltage
Abnormal high power source voltage (18.5 V or more) is detected.
Voltage of 17.5 V or less is detected
Not displayed
Low power source voltage
Abnormal low power source voltage (9.0 V or less) is detected.
Voltage of 9.3 V or more is detected
Not displayed
Abnormal height control sensor signal while initialization
Initialization is performed outside the valid range of the voltage for initialization.
Initialization is successfully completed within the valid range of the voltage for initialization.
Displayed