INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT FRONT DOOR LOCK ASSEMBLY (DRIVER SIDE) |
Inspect the door lock motor & unlock detection switch.

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
- LHD Models:
Tester Connection
Door Lock Condition
Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4
ON (Door lock set to UNLOCK)
7 - 8 (Below 1 Ω)
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1
OFF (Door lock set to LOCK)
7 - 8 (10 kΩ or higher)
Measure the resistance when the switch is operated according to the value(s) in the table below.

- Standard resistance:
- RHD Models:
Tester Connection
Door Lock Condition
Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4
ON (Door lock set to UNLOCK)
7 - 8 (Below 1 Ω)
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1
OFF (Door lock set to LOCK)
7 - 8 (10 kΩ or higher)
Inspect the key lock and unlock switch.

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
- LHD Models:
Tester Connection
Door Lock Condition
Specified Condition
10 - 7
ON (Door lock set to UNLOCK)
Below 1 Ω
9 - 7
OFF (Door lock set to LOCK)
Below 1 Ω
Measure the resistance when the switch is operated according to the value(s) in the table below.

- Standard resistance:
- RHD Models:
Tester Connection
Door Lock Condition
Specified Condition
5 - 8
ON (Door lock set to UNLOCK)
Below 1 Ω
6 - 8
OFF (Door lock set to LOCK)
Below 1 Ω
| REMOVE FRONT DOOR LOCK ASSEMBLY (FRONT PASSENGER SIDE) |
Inspect the door lock motor.

Apply battery voltage and check operation of the door lock motor.
- Standard:
- LHD Models:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1
Lock
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4
Unlock
Apply battery voltage and check operation of the door lock motor.

- Standard:
- RHD Models:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1
Lock
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4
Unlock
Inspect the key lock and unlock switch.

Measure the resistance when the switch is operated according to the value(s) in the table below.
- Standard resistance:
- LHD Models:
Tester Connection
Door Lock Condition
Specified Condition
5 - 8
ON (Door lock set to UNLOCK)
Below 1 Ω
6 - 8
OFF (Door lock set to LOCK)
Below 1 Ω
Measure the resistance when the switch is operated according to the value(s) in the table below.

- Standard resistance:
- RHD Models:
Tester Connection
Door Lock Condition
Specified Condition
10 - 7
ON (Door lock set to UNLOCK)
Below 1 Ω
9 - 7
OFF (Door lock set to LOCK)
Below 1 Ω