INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT KNOCK CONTROL SENSOR |
 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 (Ground) - 2 (Output)
|
20°C (68°F)
|
120 to 280 kΩ
|
If the result is not as specified, replace the knock control sensor.