INSPECTION
Inspection · Vehicles built from Jan 2015
Versions by build date: Oct 2014 – Dec 2014 from Jan 2015
| INSPECT STARTER ASSEMBLY (for 1.6 kW Type) |
- CAUTION:
- As a large electric current passes through the cable during this inspection, a thick cable must be used. If not, the cable may become hot and cause injury.
- NOTICE:
- The following tests must each be performed within 3 to 5 seconds to prevent the coil from burning out.
Mount the starter assembly in a vise between aluminum plates.
Perform the pull-in test.
Remove the nut and disconnect the lead wire from terminal C.
Connect the battery to the magnet starter switch as shown in the illustration. Check that the clutch pinion gear extends.

If the clutch pinion gear does not move, replace the magnet starter switch assembly.Text in Illustration *a
Terminal 50
*b
Terminal C
Perform the holding test.
Maintain the battery connections of the pull-in test above, but disconnect the negative (-) lead from terminal C. Check that the pinion gear remains extended.

If the clutch pinion gear returns inward, replace the magnet starter switch assembly.Text in Illustration *a
Terminal C
Inspect the clutch pinion gear return.
Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns.

If the clutch pinion gear does not return, replace the magnet starter switch assembly.Text in Illustration *a
Starter Body
Perform the no-load performance test.
Connect the lead wire to terminal C with the nut. Make sure that the lead wire is not grounded.
- Torque:
- 10 N*m{ 102 kgf*cm , 7 ft.*lbf }
Connect the battery and ammeter (AC/DC 400A probe) to the starter as shown in the illustration.

Text in Illustration *a
Terminal 50
*b
Terminal 30
*c
AC/DC 400A Probe
Check that the starter rotates smoothly and steadily while the pinion gear is moving out. Then measure the current.
- Standard current:
- 90 A or less at 11.5 V
| INSPECT STARTER ASSEMBLY (for 1.7 kW Type) |
- CAUTION:
- As a large electric current passes through the cable during this inspection, a thick cable must be used. If not, the cable may become hot and cause injury.
- NOTICE:
- The following tests must each be performed within 3 to 5 seconds to prevent the coil from burning out.
Mount the starter assembly in a vise between aluminum plates.
Perform pull-in test.
Remove the nut, and then disconnect the lead wire from terminal C.
Connect the battery to the magnet starter switch as shown in the illustration. Then check that the clutch pinion gear moves outward. If the clutch pinion gear does not move, replace the magnet starter switch assembly.

Text in Illustration *a
Terminal 50
*b
Terminal C
Perform holding test.
When the battery is connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear returns out.

If the clutch pinion gear returns inward, replace the magnet starter switch assembly.Text in Illustration *a
Terminal C
Inspect clutch pinion gear return.
Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.

If the clutch pinion gear does not return inward, replace the magnet starter switch assembly.Text in Illustration *a
Starter Body
Perform operation test without load.
Connect the lead wire to terminal C.
- Torque:
- 8.0 N*m{ 82 kgf*cm , 71 in.*lbf }
Connect the battery and ammeter (AC/DC 400A probe) to the starter as shown in the illustration.

Text in Illustration *a
Terminal 50
*b
Terminal 30
*c
AC/DC 400A Probe
Check that the starter rotates smoothly and steadily while the pinion gear is moving outward. Then measure the current.
- Standard current:
- 90 A or less at 10.9 V
| INSPECT STARTER ASSEMBLY (for 2.0 kW Type) |
- CAUTION:
- As a large electric current passes through the cable during this inspection, a thick cable must be used. If not, the cable may become hot and cause injury.
- NOTICE:
- The following tests must each be performed within 3 to 5 seconds to prevent the coil from burning out.
Mount the starter assembly in a vise between aluminum plates.
Perform pull-in test.
Remove the nut, and then disconnect the lead wire from terminal C.
Connect the battery to the magnet starter switch as shown in the illustration. Check that the clutch pinion gear extends.

If the clutch pinion gear does not move, inspect the magnet starter switch assembly. If the magnet starter switch assembly is not as specified, replace it.Text in Illustration *a
Terminal 50
*b
Terminal C
Perform holding test.

Disconnect the negative (-) terminal lead from terminal C with the condition specified in the pull-in test above being maintained. Check that the pinion gear remains extended.
If the clutch pinion gear returns inward, inspect the magnet starter switch assembly. If the magnet starter switch assembly is not as specified, replace it.Text in Illustration *a
Terminal C
Inspect the clutch pinion gear return.

Text in Illustration *a
Starter Body
Disconnect the negative (-) terminal lead from the starter body. Check that the clutch pinion gear returns inward.
If the clutch pinion gear does not return inward, inspect the magnet starter switch assembly. If the magnet starter switch assembly is not as specified, replace it.
Perform operation test without load.
Connect the lead wire to terminal C.
- Torque:
- 5.9 N*m{ 60 kgf*cm , 52 in.*lbf }
Connect the battery and ammeter (AC/DC 400A probe) to the starter as shown in the illustration.

Text in Illustration *a
Terminal 50
*b
Terminal 30
*c
AC/DC 400A Probe
Check that the starter rotates smoothly and steadily while the pinion gear is extended. Then measure the current.
- Standard current:
- 100 A or less at 11.5 V
- HINT:
- Inspect the starter brush holder assembly, starter yoke assembly and starter armature assembly. If there is a malfunction, replace the part and perform this test again.