2014-2019 Hiace · Service Manual BODY ELECTRICAL

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Oct 2014


CHECK AUTOMATIC LIGHT CONTROL SENSOR (for LHD)

  1. E232463E01
    Disconnect the I10 automatic light control sensor connector.
    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Automatic Light Control Sensor)

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    I10-1 (CLTB) - I10-3 (CLTE)
    Ignition switch off
    Below 1 V
    Ignition switch on (IG)
    10 to 14 V

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I10-3 (CLTE) - Body ground
    Always
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.

  1. B113713E01
    Reconnect the I10 automatic light control sensor connector.
    Text in Illustration 
    *a
    Component with harness connected
    (Automatic Light Control Sensor)

  1. Connect an oscilloscope to the automatic light control sensor connector.

  1. B113714E01
    Check the waveform.

    OK:
    Tester Connection
    Tool Setting
    Switch Condition
    Specified Condition
    I10-3 (CLTE) - I10-4 (CLTS)
    5 V/DIV., 5 ms./DIV
    Ignition switch on (IG), light control switch in AUTO position
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.

    If the result is not as specified, the automatic light control sensor may have a malfunction.


CHECK AUTOMATIC LIGHT CONTROL SENSOR (for RHD)

  1. B109993E83
    Disconnect the I22 automatic light control sensor connector.
    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Automatic Light Control Sensor)

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    I22-3 (CLTB) - I22-6 (CLTE)
    Ignition switch off
    Below 1 V
    Ignition switch on (IG)
    10 to 14 V

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    I22-6 (CLTE) - Body ground
    Always
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.

  1. E232182E01
    Reconnect the I22 automatic light control sensor connector.
    Text in Illustration 
    *a
    Component with harness connected
    (Automatic Light Control Sensor)

  1. Connect an oscilloscope to the automatic light control sensor connector.

  1. B113714E01
    Check the waveform.

    OK:
    Tester Connection
    Tool Setting
    Switch Condition
    Specified Condition
    I22-6 (CLTE) - I22-4 (CLTS)
    5 V/DIV., 5 ms./DIV
    Ignition switch on (IG), light control switch in AUTO position
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.

    If the result is not as specified, the automatic light control sensor may have a malfunction.

← COMPONENTS (from Oct 2014)REMOVAL (from Oct 2014) →