2014-2019 Hiace · Service Manual ENGINE

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Oct 2014


INSPECT COOLING FAN SYSTEM
  1. Put the vehicle in the following state:

    1. The ignition switch is off.

    2. w/ DPF:
      The coolant temperature is less than 74°C (165°F).

    3. w/o DPF:
      The coolant temperature is less than 75°C (167°F).

    4. The battery voltage is between 11 and 14 V.

    5. w/ Air Conditioning System:
      The A/C switch is off.

  1. Turn the ignition switch to ON (engine off) and wait for approximately 10 seconds. Check that the fans do not operate.

  1. Start the engine. Check that the fans do not operate with the engine idling.

    HINT:
    1. w/ DPF:
      Make sure that the radiator coolant temperature is less than 74°C (165°F), and that the A/C switch is off.
    2. w/o DPF:
      Make sure that the radiator coolant temperature is less than 75°C (167°F), and that the A/C switch is off (w/ Air Conditioning System).

  1. w/ Air Conditioning System:
    Check that the fans operate when the A/C switch is turned on (The temperature is set to MAX COOL and the magnet clutch is operating).

  1. Check that the fans operate when the coolant sensor connector is disconnected.

  1. After the engine has warmed up, the fan operates as shown in the illustration.

    1. w/ DPF:

      A242204E02

      A242205E02

      HINT:
      1. No. 1 cooling fan motor:
        The coolant temperature at which the fans start to operate is approximately 76°C (169°F).
      2. No. 2 cooling fan motor:
        The coolant temperature at which the fans start to operate is approximately 77°C (171°F).
      3. This system can also be checked using the GTS.
      4. Enter the following menus: Powertrain / Engine and ECT / Data List / Initial Engine Coolant Temp.

    2. w/o DPF:

      A156775E04

      HINT:
      1. The coolant temperature at which the fans start to operate is approximately 77°C (171°F).
      2. This system can also be checked using the GTS.
      3. Enter the following menus: Powertrain / Engine and ECT / Data List / Initial Engine Coolant Temp.


INSPECT NO. 1 COOLING FAN MOTOR

HINT:
Terminals of ECM
  1. w/ DPF: (Click here)
  2. w/o DPF: (Click here)

  1. A238531E03
    Check the input voltage.
    Text in Illustration 
    *a
    Component without harness connected
    (No. 1 Cooling Fan Motor)

    1. Disconnect the No. 1 cooling fan motor connector.

    2. Turn the ignition switch to ON.
      Measure the voltage at the +B1 terminal of the disconnected harness side connector.

      Standard voltage:
      11 to 14 V

    3. If the terminal voltage is not within the specification, inspect the power source system (fusible link, fuse, wire harness and relay).

  1. Inspect the wire harness.

    1. Disconnect the ECM and No. 1 cooling fan motor connectors.

    2. Measure the resistance between ECM terminal RFC and cooling fan motor terminal SI.

      Standard resistance:
      Below 1 Ω

      HINT:
      If the fan does not operate, there may be a short circuit. If the fan remains operating, there may be an open circuit.

    3. Inspect the ECM power source circuit and ground circuit.

  1. Inspect the input signal.

    NOTICE:
    1. w/ DPF:
      Be sure to perform the inspection with the radiator coolant temperature less than 74°C (165°F).
    2. w/o DPF:
      Be sure to perform the inspection with the radiator coolant temperature less than 75°C (167°F).


    1. Set the oscilloscope.

    2. A103358E02
      Using the oscilloscope, check the waveform between No. 1 cooling fan motor terminals E1 and SI.

      Standard:
      Condition
      Input Signal
      Engine stopped
      IG switch ON
      Waveform 1
      (Duty ratio 0%)
      Engine idling
      A/C OFF
      Waveform 1
      (0%)
      Engine idling
      A/C ON
      Waveform 2
      1. w/ DPF
        (45 to 70%)
      2. w/o DPF
        (40 to 70%)
      Engine idling and ECT sensor connector disconnected
      Waveform 3
      (70%)

      HINT:
      If the input signal is abnormal, there is a malfunction in the ECM or cooling fan motor.


INSPECT NO. 2 COOLING FAN MOTOR (w/ Air Conditioning System)

HINT:
Terminals of ECM
  1. w/ DPF: (Click here)
  2. w/o DPF: (Click here)

  1. A238531E04
    Check the input voltage.
    Text in Illustration 
    *a
    Component without harness connected
    (No. 2 Cooling Fan Motor)

    1. Disconnect the No. 2 cooling fan motor connector.

    2. Turn the ignition switch to ON.
      Measure the voltage at the +B2 terminal of the disconnected harness side connector.

      Standard voltage:
      11 to 14 V

    3. If the terminal voltage is not within the specification, inspect the power source system (fusible link, fuse, wire harness and relay).

  1. Inspect the wire harness.

    1. Disconnect the ECM and No. 2 cooling fan motor connectors.

    2. Measure the resistance between ECM terminal RFC2 and cooling fan motor terminal SI2.

      Standard resistance:
      Below 1 Ω

      HINT:
      If the fan does not operate, there may be a short circuit. If the fan remains operating, there may be an open circuit.

    3. Inspect the ECM power source circuit and ground circuit.

  1. Inspect the input signal.

    NOTICE:
    1. w/ DPF:
      Be sure to perform the inspection with the radiator coolant temperature less than 74°C (165°F).
    2. w/o DPF:
      Be sure to perform the inspection with the radiator coolant temperature less than 75°C (167°F).


    1. Set the oscilloscope.

    2. A103358E02
      Using the oscilloscope, check the waveform between No. 2 cooling fan motor terminals E2 and SI2.

      Standard:
      Condition
      Input Signal
      Engine stopped
      IG switch ON
      Waveform 1
      (Duty ratio 0%)
      Engine idling
      A/C OFF
      Waveform 1
      (0%)
      Engine idling
      A/C ON
      Waveform 2
      (40 to 60%)
      Engine idling and ECT sensor connector disconnected
      Waveform 3
      (70%)

      HINT:
      If the input signal is abnormal, there is a malfunction in the ECM or cooling fan motor.

← SYSTEM DIAGRAM (from Oct 2014)REPLACEMENT (Oct 2014 – Mar 2016) →