ON-VEHICLE INSPECTION
Inspection · Vehicles built from Jan 2017
| INSPECT COOLING FAN SYSTEM |
Put the vehicle in the following state:
The ignition switch is off.
The coolant temperature is less than 74°C (165°F).
The battery voltage is between 11 and 14 V.
The A/C switch is off.
Turn the ignition switch to ON (engine off) and wait for approximately 10 seconds. Check that the fans do not operate.
Start the engine. Check that the fans do not operate with the engine idling.
- HINT:
- Make sure that the radiator coolant temperature is less than 74°C (165°F), and that the A/C switch is off.
- Make sure that the radiator coolant temperature is less than 74°C (165°F), and that the A/C switch is off.
Check that the fans operate when the coolant sensor connector is disconnected.
After the engine has warmed up, the fan operates as shown in the illustration.




- HINT:
- No. 1 cooling fan motor:
The coolant temperature at which the fans start to operate is approximately 76°C (169°F).
- No. 2 cooling fan motor:
The coolant temperature at which the fans start to operate is approximately 77°C (171°F).
- This system can also be checked using the GTS.
- Enter the following menus: Powertrain / Engine and ECT / Data List / Initial Engine Coolant Temp.
- No. 1 cooling fan motor:
| INSPECT NO. 1 COOLING FAN MOTOR |
- HINT:
- Terminals of ECM
- (Click here)
Check the input voltage.
Disconnect the No. 1 cooling fan motor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
B90-3 (+B1) - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness
(to No. 1 Cooling Fan connector)
If the terminal voltage is not within the specification, inspect the power source system (fusible link, fuse, wire harness and relay).
Inspect the wire harness.
Disconnect the ECM and No. 1 cooling fan motor connectors.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Specified Condition
B97-60 (RFC) - B90-2 (SI)
Below 1Ω
Text in Illustration *a
Front view of wire harness
(to No. 1 Cooling Fan connector)
- HINT:
- If the fan does not operate, there may be a short circuit. If the fan remains operating, there may be an open circuit.
Inspect the ECM power source circuit and ground circuit.
Inspect the input signal.
- NOTICE:
- Be sure to perform the inspection with the radiator coolant temperature less than 74°C (165°F).
- Be sure to perform the inspection with the radiator coolant temperature less than 74°C (165°F).
Set the oscilloscope.
Using the oscilloscope, check the waveform between No. 1 cooling fan motor terminals E1 and SI.

- Standard:
Condition
Input Signal
Engine stopped
IG switch ON
Waveform 1
(Duty ratio 0%)
Engine idling
A/C OFF
Waveform 1
(0%)
Engine idling
A/C ON
Waveform 2
(45 to 70%)
Engine idling and ECT sensor connector disconnected
Waveform 3
(70%)
- HINT:
- If the input signal is abnormal, there is a malfunction in the ECM or cooling fan motor.
| INSPECT NO. 2 COOLING FAN MOTOR |
- HINT:
- Terminals of ECM
- (Click here)
Check the input voltage.
Disconnect the No. 2 cooling fan motor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
B91-3 (+B2) - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness
(to No. 2 Cooling Fan connector)
If the terminal voltage is not within the specification, inspect the power source system (fusible link, fuse, wire harness and relay).
Inspect the wire harness.
Disconnect the ECM and No. 2 cooling fan motor connectors.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Specified Condition
B97-58 (RFC2) - B91-2 (SI2)
Below 1Ω
Text in Illustration *a
Front view of wire harness
(to No. 2 Cooling Fan connector)
- HINT:
- If the fan does not operate, there may be a short circuit. If the fan remains operating, there may be an open circuit.
Inspect the ECM power source circuit and ground circuit.
Inspect the input signal.
- NOTICE:
- Be sure to perform the inspection with the radiator coolant temperature less than 74°C (165°F).
- Be sure to perform the inspection with the radiator coolant temperature less than 74°C (165°F).
Set the oscilloscope.
Using the oscilloscope, check the waveform between No. 2 cooling fan motor terminals E2 and SI2.

- Standard:
Condition
Input Signal
Engine stopped
IG switch ON
Waveform 1
(Duty ratio 0%)
Engine idling
A/C OFF
Waveform 1
(0%)
Engine idling
A/C ON
Waveform 2
(40 to 60%)
Engine idling and ECT sensor connector disconnected
Waveform 3
(70%)
- HINT:
- If the input signal is abnormal, there is a malfunction in the ECM or cooling fan motor.
