P0405 Exhaust Gas Recirculation Sensor "A" Circuit Low
Diagnostic trouble codes · Vehicles built from Jan 2017
Also covers:
- P0406 Exhaust Gas Recirculation Sensor "A" Circuit High
DESCRIPTION
The EGR valve position sensor is mounted on the electric EGR control valve assembly and used for detecting the EGR valve angle. The EGR valve angle detected by the sensor is sent to the ECM as feedback. The ECM then regulates the EGR valve angle in accordance with engine running conditions.| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 2 seconds or more |
EGR valve position sensor output voltage is less than 0.2 V for 2 seconds. (1 trip detection logic) |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 2 seconds or more |
EGR valve position sensor output voltage is higher than 4.8 V for 2 seconds. (1 trip detection logic) |
|
MONITOR DESCRIPTION
When the output voltage of the EGR valve position sensor deviates from the normal operating range of 0.2 to 4.8 V for more than 2 seconds, the ECM interprets this as a malfunction of the sensor circuit and illuminates the MIL.WIRING DIAGRAM
Refer to DTC P042E (Click here).INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. CHECK HARNESS AND CONNECTOR (EGR VALVE POSITION SENSOR - ECM) |
Disconnect the electric EGR control valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D123-3 (VC) - D134-128 (VCEG)
Always
Below 1 Ω
D123-2 (VTA) - D134-126 (EGLS)
Always
Below 1 Ω
D123-1 (E2) - D134-127 (EEGL)
Always
Below 1 Ω
D123-3 (VC) or D134-128 (VCEG) - Body ground and other terminals
Always
10 kΩ or higher
D123-2 (VTA) or D134-126 (EGLS) - Body ground and other terminals
Always
10 kΩ or higher
Reconnect the electric EGR control valve assembly connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR |
Disconnect the electric EGR control valve assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
D123-3 (VC) - D123-1 (E2)
Ignition switch ON
4.5 to 5.5 V
Text in Illustration *a
Front view of wire harness connector
(to Electric EGR control valve assembly)
Reconnect the electric EGR control valve assembly connector.
|
|
||||
| OK | |
| 3. CHECK ECM (CHECK RESISTANCE) |
Disconnect the electric EGR control valve assembly connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
D123-3 (VC) - D123-2 (VTA)
Ignition switch off
No short or no open
D123-2 (VTA) - D123-1 (E2)
Text in Illustration *a
Front view of wire harness connector
(to Electric EGR control valve assembly)
Reconnect the electric EGR control valve assembly connector.
|
|
||||
| OK | |
| 4. REPLACE ELECTRIC EGR CONTROL VALVE ASSEMBLY |
Replace the electric EGR control valve assembly (Click here).
|
|
||||
| 5. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace the harness or connector.
|
|
||||
| 6. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 7. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the GTS to the DLC3.
Clear the DTCs (Click here).
Turn the ignition switch to ON for 2 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTC is not output again.
| NEXT | ||
| ||