When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil of the No. 1 integration relay (EFI), closing the contacts and supplying power to terminals +B of the ECM.
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1. CHECK NO. 1 INTEGRATION RELAY (POWER SOURCE)
Remove the No. 1 integration relay from the No. 1 engine room relay block.
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
10C-1 - Body ground
Always
11 to 14 V
Text in Illustration
*a
Front view of wire harness connector (to No. 1 Integration Relay)
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (NO. 1 INTEGRATION RELAY - BATTERY)
OK
2. INSPECT NO. 1 INTEGRATION RELAY (EFI)
Inspect the No. 1 integration relay (EFI) (Click here).
NG
REPLACE NO. 1 INTEGRATION RELAY
OK
3. CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - ECM, BODY GROUND)
Remove the No. 1 integration relay from the No. 1 engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
B94-46 (MREL) - 10A-6
Always
Below 1 Ω
B94-2 (+B) - 10A-8
Always
Below 1 Ω
B94-3 (+B2) - 10A-8
Always
Below 1 Ω
10A-7 - Body ground
Always
Below 1 Ω
B94-46 (MREL) or 10A-6 - Body ground
Always
10 kΩ or higher
B94-2 (+B) or 10A-8 - Body ground
Always
10 kΩ or higher
B94-3 (+B2) or 10A-8 - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
D116-59 (E1) - Body ground
Always
Below 1 Ω
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
5. INSPECT ECM (IGSW VOLTAGE)
Disconnect the ECM connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.