2014-2019 Hiace · Service Manual BODY

TERMINALS OF ECU

System information · Vehicles built from Oct 2014


CHECK DOOR CONTROL RELAY ASSEMBLY (for LH Side)

  1. Disconnect the q3 and q4 door control relay assembly connectors.
    B365268E01

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    q3-7 (GND) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    q3-8 (B) - Body ground
    B-R - Body ground
    Battery power supply
    Always
    11 to 14 V
    q4-9 (IG) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch ON
    11 to 14 V
    q4-9 (IG) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch off
    Below 1 V
    q4-11 (ECUB) - Body ground
    W - Body ground
    Battery power supply
    Always
    11 to 14 V
    q4-21 (SEL) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω

  3. Reconnect the q3 and q4 door control relay assembly connectors.

  4. Measure the voltage and resistance according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    q3-1 (DC-) - Body ground
    P - Body ground
    Slide door lock closer motor drive output
    Slide door LH fully open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    q3-2 (CL+) - Body ground
    Y-B - Body ground
    Slide door clutch output
    Slide door LH fully close → auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
    Below 1 V → 11 to 14 V → Below 1 V
    q3-3 (SD-) - Body ground
    B - Body ground
    Slide door motor low open speed drive output
    Slide door LH fully close, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → low speed range → slide door LH fully open
    Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
    q3-4 (SD+) - Body ground
    L - Body ground
    Slide door motor high open speed drive output
    Slide door LH fully close, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → low speed range → slide door LH fully open
    Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
    q3-5 (DC+) - Body ground
    L - Body ground
    Slide door lock closer motor driver output
    Slide door LH fully open, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → slide door LH halfway → slide door LH fully close
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    q3-6 (CL-) - Body ground
    Y-R - Body ground
    Slide door clutch output
    Slide door fully open, auto slide door control switch assembly off → on or ley's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
    Below 1 V → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → Below 1 V
    q4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door fully open, auto slide door control switch assembly off → on or ley's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
    Below 1 V → 11 to 14 V (approximately 0.8 seconds) → Below 1 V
    q4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door LH fully close → slide door LH fully open (assist operation) → slide door LH open operation
    11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
    q4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door fully open, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH close operation
    11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
    q4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door LH fully open → inside handle or outside handle pulled → slide door LH close operation
    11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
    q4-3 (DSV) - Body ground
    P - Body ground
    Slide door drive unit pulse sensor power supply
    Ignition switch ON
    11 to 14 V
    q4-3 (DSV) - Body ground
    P - Body ground
    Slide door drive unit pulse sensor power supply
    Ignition switch off
    Below 1 V
    q4-8 (MPX1) - Body ground
    Y - Body ground
    Handle switch input
    Inside handle or outside handle not pulled → pulled
    10 kΩ or higher → Below 1 Ω
    q4-10 (CPSW) - Body ground
    R - Body ground
    Park/neutral position switch input
    Ignition switch ON, shift lever P position → except P position
    11 to 14 V → Below 1 V
    q4-12 (RACT) - Body ground
    R-B - Body ground
    Slide door lock release motor drive output
    Slide door LH fully close, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
    Below 1 V → 11 to 14 V → Below 1 V
    q4-14 (OS) - Body ground
    G - Body ground
    Power slide door sensor assembly input
    Power slide door sensor assembly pushed → not pushed
    Approximately below 100Ω → Approximately below 1k Ω
    q4-15 (PKB) - Body ground
    B - Body ground
    Parking brake switch input
    Parking brake lever pulled → not pulled
    10 kΩ or higher → Below 1 Ω
    q4-16 (DSW) - Body ground
    Y - Body ground
    Auto slide door control switch assembly input
    Auto slide door control switch assembly off → on
    Below 1 Ω → 10 kΩ or higher
    q4-17 (MSW) - Body ground
    V - Body ground
    Auto slide door main switch input
    Auto slide door main switch off → on
    Below 1 Ω → 10 kΩ or higher
    q4-20 (MPX2) - Body ground
    L - Body ground
    Handle switch input
    Inside handle or outside handle not pulled → pulled
    Below 1 Ω → 10 kΩ or higher
    q4-22 (DLSW) - Body ground
    GR - Body ground
    Door unlock position switch input
    Slide door LH fully open, slide door LH unlock → lock
    Below 1 Ω → 10 kΩ or higher
    q4-23 (DS2) - Body ground
    B - Body ground
    Slide door drive unit pulse sensor input
    Slide door LH fully close → slide door LH open operation → slide door LH fully open → slide door LH close operation → slide door LH fully close
    Below 1 V → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → 11 to 14 V (slide door fully open) → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → Below 1 V
    q4-24 (DS1) - Body ground
    LG - Body ground
    Slide door drive unit pulse sensor input
    Slide door LH fully close → slide door open operation → slide door LH fully open → slide door LH close operation → slide door LH fully close
    Below 1 V → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → 11 to 14 V (slide door LH fully open) → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → Below 1 V


CHECK DOOR CONTROL RELAY ASSEMBLY (for RH Side, w/ Power Slide Door)

  1. Disconnect the I3 and I4 door control relay assembly connectors.
    B365268E02

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    I3-7 (GND) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    I3-8 (B) - Body ground
    B-R - Body ground
    Battery power supply
    Always
    11 to 14 V
    I4-9 (PCV1) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch ON
    11 to 14 V
    I4-9 (PCV1) - Body ground
    B - Body ground
    Ignition power supply
    Ignition switch off
    Below 1 V
    I4-11 (ECUB) - Body ground
    W - Body ground
    Battery power supply
    Always
    11 to 14 V
    I4-21 (SEL) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω

  3. Reconnect the I3 and I4 door control relay assembly connectors.

  4. Measure the voltage and resistance according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    I3-1 (DC-) - Body ground
    P - Body ground
    Slide door lock closer motor drive output
    Slide door RH fully open → halfway position → normal rotation operation → revers rotation operation → operation stop
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    I3-2 (CL+) - Body ground
    Y-B - Body ground
    Slide door clutch output
    Slide door RH fully close → auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
    Below 1 V → 11 to 14 V → Below 1 V
    I3-3 (SD-) - Body ground
    B - Body ground
    Slide door motor low open speed drive output
    Slide door RH fully close, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → low speed range → slide door RH fully open
    Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
    I3-4 (SD+) - Body ground
    L - Body ground
    Slide door motor high open speed drive output
    Slide door RH fully close, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → low speed range → slide door RH fully open
    Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
    I3-5 (DC+) - Body ground
    L - Body ground
    Slide door lock closer motor driver output
    Slide door RH fully open, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → slide door RH halfway → slide door RH fully close
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    I3-6 (CL-) - Body ground
    Y-R - Body ground
    Slide door clutch output
    Slide door fully open, auto slide door control switch assembly off → on or ley's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
    Below 1 V → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → Below 1 V
    I4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door fully open, auto slide door control switch assembly off → on or ley's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
    Below 1 V → 11 to 14 V (approximately 0.8 seconds) → Below 1 V
    I4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door RH fully close → slide door RH fully open (assist operation) → slide door RH open operation
    11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
    I4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door fully open, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH close operation
    11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
    I4-1 (BZR) - Body ground
    W - Body ground
    Slide door warning buzzer output
    Slide door RH fully open → inside handle or outside handle pulled → slide door RH close operation
    11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
    I4-3 (DSV) - Body ground
    P - Body ground
    Slide door drive unit pulse sensor power supply
    Ignition switch ON
    11 to 14 V
    I4-3 (DSV) - Body ground
    P - Body ground
    Slide door drive unit pulse sensor power supply
    Ignition switch off
    Below 1 V
    I4-8 (MPX1) - Body ground
    Y - Body ground
    Handle switch input
    Inside handle or outside handle not pulled → pulled
    10 kΩ or higher → Below 1 Ω
    I4-10 (CPSW) - Body ground
    R - Body ground
    Park/neutral position switch input
    Ignition switch ON, shift lever P position → except P position
    11 to 14 V → Below 1 V
    I4-12 (RACT) - Body ground
    R-B - Body ground
    Slide door lock release motor drive output
    Slide door RH fully close, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
    Below 1 V → 11 to 14 V → Below 1 V
    I4-14 (OS) - Body ground
    G - Body ground
    Power slide door sensor assembly input
    Power slide door sensor assembly pushed → not pushed
    Approximately below 100Ω → Approximately below 1k Ω
    I4-15 (PKB) - Body ground
    B - Body ground
    Parking brake switch input
    Parking brake lever pulled → not pulled
    10 kΩ or higher → Below 1 Ω
    I4-16 (DSW) - Body ground
    Y - Body ground
    Auto slide door control switch assembly input
    Auto slide door control switch assembly off → on
    Below 1 Ω → 10 kΩ or higher
    I4-17 (MSW) - Body ground
    V - Body ground
    Auto slide door main switch input
    Auto slide door main switch off → on
    Below 1 Ω → 10 kΩ or higher
    I4-20 (MPX2) - Body ground
    L - Body ground
    Handle switch input
    Inside handle or outside handle not pulled → pulled
    Below 1 Ω → 10 kΩ or higher
    I4-22 (DLSW) - Body ground
    GR - Body ground
    Door unlock position switch input
    Slide door RH fully open, slide door RH unlock → lock
    Below 1 Ω → 10 kΩ or higher
    I4-23 (DS2) - Body ground
    B - Body ground
    Slide door drive unit pulse sensor input
    Slide door RH fully close → slide door RH open operation → slide door RH fully open → slide door RH close operation → slide door RH fully close
    Below 1 V → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → 11 to 14 V (slide door fully open) → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → Below 1 V
    I4-24 (DS1) - Body ground
    LG - Body ground
    Slide door drive unit pulse sensor input
    Slide door RH fully close → slide door open operation → slide door RH fully open → slide door RH close operation → slide door RH fully close
    Below 1 V → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → 11 to 14 V (slide door RH fully open) → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → Below 1 V


CHECK DOOR OPENING RELAY (for LH Side)

  1. B365267E01
    Disconnect the p2 door opening relay connector.

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    p2-2 (E) - Body ground
    W-B - Body ground
    Ground
    Always
    Below 1 Ω
    p2-6 (L) - Body ground
    W - Body ground
    Power supply
    Always
    11 to 14 V
    p2-10 (E) - Body ground
    BR - Body ground
    Ground
    Always
    Below 1 Ω

  3. Reconnect the p2 door opening relay connector.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    p2-1 (L) - p2-10 (E)
    W - BR
    Slide door lock release motor output
    Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V
    p2-3 (UL1) - p2-10 (E)
    R - BR
    Slide door lock release motor output
    Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    p2-5 (SIG) - p2-10 (E)
    Y - BR
    Release position switch output
    Slide door fully open or closed → Slide door in opening operation or closing operation
    11 to 14 V → Below 1 V → 11 to 14 V
    p2-12 (P/W) - p2-10 (E)
    L - BR
    Initial position switch output
    Slide door fully open or closed → Not completely open or closed
    Below 1 V → 11 to 14 V → Below 1 V


CHECK DOOR OPENING RELAY (for RH Side, w/ Power Slide Door)

  1. B365267E02
    Disconnect the f2 door opening relay connector.

  2. Measure the resistance and voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    f2-2 (E) - Body ground
    W - Body ground
    Ground
    Always
    Below 1 Ω
    f2-6 (B) - Body ground
    B - Body ground
    Power supply
    Always
    11 to 14 V
    f2-10 (MSE) - Body ground
    BR - Body ground
    Ground
    Always
    Below 1 Ω

  3. Reconnect the f2 door opening relay connector.

  4. Measure the voltage according to the value(s) in the table below.

    Terminal No. (Symbol)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    f2-1 (DC-) - f2-10 (MSE)
    R - BR
    Slide door lock release motor output
    Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
    Below 1 V → Below 1 V → Below 1 V → 11 to 14 V
    f2-3 (DC+) - f2-10 (MSE)
    B - BR
    Slide door lock release motor output
    Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
    Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
    f2-5 (HSW) - f2-10 (MSE)
    Y - BR
    Release position switch output
    Slide door fully open or closed → Slide door in opening operation or closing operation
    11 to 14 V → Below 1 V → 11 to 14 V
    f2-12 (POS) - f2-10 (MSE)
    L - BR
    Initial position switch output
    Slide door fully open or closed → Not completely open or closed
    Below 1 V → 11 to 14 V → Below 1 V