TERMINALS OF ECU
System information · Vehicles built from Oct 2014
| CHECK DOOR CONTROL RELAY ASSEMBLY (for LH Side) |
Disconnect the q3 and q4 door control relay assembly connectors.


Measure the resistance and voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
q3-7 (GND) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
q3-8 (B) - Body ground
B-R - Body ground
Battery power supply
Always
11 to 14 V
q4-9 (IG) - Body ground
B - Body ground
Ignition power supply
Ignition switch ON
11 to 14 V
q4-9 (IG) - Body ground
B - Body ground
Ignition power supply
Ignition switch off
Below 1 V
q4-11 (ECUB) - Body ground
W - Body ground
Battery power supply
Always
11 to 14 V
q4-21 (SEL) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
Reconnect the q3 and q4 door control relay assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
q3-1 (DC-) - Body ground
P - Body ground
Slide door lock closer motor drive output
Slide door LH fully open → halfway position → normal rotation operation → revers rotation operation → operation stop
Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
q3-2 (CL+) - Body ground
Y-B - Body ground
Slide door clutch output
Slide door LH fully close → auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
Below 1 V → 11 to 14 V → Below 1 V
q3-3 (SD-) - Body ground
B - Body ground
Slide door motor low open speed drive output
Slide door LH fully close, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → low speed range → slide door LH fully open
Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
q3-4 (SD+) - Body ground
L - Body ground
Slide door motor high open speed drive output
Slide door LH fully close, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → low speed range → slide door LH fully open
Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
q3-5 (DC+) - Body ground
L - Body ground
Slide door lock closer motor driver output
Slide door LH fully open, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → slide door LH halfway → slide door LH fully close
Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
q3-6 (CL-) - Body ground
Y-R - Body ground
Slide door clutch output
Slide door fully open, auto slide door control switch assembly off → on or ley's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
Below 1 V → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → Below 1 V
q4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door fully open, auto slide door control switch assembly off → on or ley's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
Below 1 V → 11 to 14 V (approximately 0.8 seconds) → Below 1 V
q4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door LH fully close → slide door LH fully open (assist operation) → slide door LH open operation
11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
q4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door fully open, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH close operation
11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
q4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door LH fully open → inside handle or outside handle pulled → slide door LH close operation
11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
q4-3 (DSV) - Body ground
P - Body ground
Slide door drive unit pulse sensor power supply
Ignition switch ON
11 to 14 V
q4-3 (DSV) - Body ground
P - Body ground
Slide door drive unit pulse sensor power supply
Ignition switch off
Below 1 V
q4-8 (MPX1) - Body ground
Y - Body ground
Handle switch input
Inside handle or outside handle not pulled → pulled
10 kΩ or higher → Below 1 Ω
q4-10 (CPSW) - Body ground
R - Body ground
Park/neutral position switch input
Ignition switch ON, shift lever P position → except P position
11 to 14 V → Below 1 V
q4-12 (RACT) - Body ground
R-B - Body ground
Slide door lock release motor drive output
Slide door LH fully close, auto slide door control switch assembly off → on or key's slide door LH switch pushed → slide door LH open operation → slide door LH fully open
Below 1 V → 11 to 14 V → Below 1 V
q4-14 (OS) - Body ground
G - Body ground
Power slide door sensor assembly input
Power slide door sensor assembly pushed → not pushed
Approximately below 100Ω → Approximately below 1k Ω
q4-15 (PKB) - Body ground
B - Body ground
Parking brake switch input
Parking brake lever pulled → not pulled
10 kΩ or higher → Below 1 Ω
q4-16 (DSW) - Body ground
Y - Body ground
Auto slide door control switch assembly input
Auto slide door control switch assembly off → on
Below 1 Ω → 10 kΩ or higher
q4-17 (MSW) - Body ground
V - Body ground
Auto slide door main switch input
Auto slide door main switch off → on
Below 1 Ω → 10 kΩ or higher
q4-20 (MPX2) - Body ground
L - Body ground
Handle switch input
Inside handle or outside handle not pulled → pulled
Below 1 Ω → 10 kΩ or higher
q4-22 (DLSW) - Body ground
GR - Body ground
Door unlock position switch input
Slide door LH fully open, slide door LH unlock → lock
Below 1 Ω → 10 kΩ or higher
q4-23 (DS2) - Body ground
B - Body ground
Slide door drive unit pulse sensor input
Slide door LH fully close → slide door LH open operation → slide door LH fully open → slide door LH close operation → slide door LH fully close
Below 1 V → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → 11 to 14 V (slide door fully open) → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → Below 1 V
q4-24 (DS1) - Body ground
LG - Body ground
Slide door drive unit pulse sensor input
Slide door LH fully close → slide door open operation → slide door LH fully open → slide door LH close operation → slide door LH fully close
Below 1 V → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → 11 to 14 V (slide door LH fully open) → Alternating 11 to 14 V and below 1 V (slide door LH in operation) → Below 1 V
| CHECK DOOR CONTROL RELAY ASSEMBLY (for RH Side, w/ Power Slide Door) |
Disconnect the I3 and I4 door control relay assembly connectors.


Measure the resistance and voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
I3-7 (GND) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
I3-8 (B) - Body ground
B-R - Body ground
Battery power supply
Always
11 to 14 V
I4-9 (PCV1) - Body ground
B - Body ground
Ignition power supply
Ignition switch ON
11 to 14 V
I4-9 (PCV1) - Body ground
B - Body ground
Ignition power supply
Ignition switch off
Below 1 V
I4-11 (ECUB) - Body ground
W - Body ground
Battery power supply
Always
11 to 14 V
I4-21 (SEL) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
Reconnect the I3 and I4 door control relay assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
I3-1 (DC-) - Body ground
P - Body ground
Slide door lock closer motor drive output
Slide door RH fully open → halfway position → normal rotation operation → revers rotation operation → operation stop
Below 1 V → Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
I3-2 (CL+) - Body ground
Y-B - Body ground
Slide door clutch output
Slide door RH fully close → auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
Below 1 V → 11 to 14 V → Below 1 V
I3-3 (SD-) - Body ground
B - Body ground
Slide door motor low open speed drive output
Slide door RH fully close, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → low speed range → slide door RH fully open
Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
I3-4 (SD+) - Body ground
L - Body ground
Slide door motor high open speed drive output
Slide door RH fully close, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → low speed range → slide door RH fully open
Below 1 V → Below 1 V → 11 to 14 V → Approximately 8 V → Below 1 V
I3-5 (DC+) - Body ground
L - Body ground
Slide door lock closer motor driver output
Slide door RH fully open, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → slide door RH halfway → slide door RH fully close
Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
I3-6 (CL-) - Body ground
Y-R - Body ground
Slide door clutch output
Slide door fully open, auto slide door control switch assembly off → on or ley's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
Below 1 V → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → Below 1 V
I4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door fully open, auto slide door control switch assembly off → on or ley's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
Below 1 V → 11 to 14 V (approximately 0.8 seconds) → Below 1 V
I4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door RH fully close → slide door RH fully open (assist operation) → slide door RH open operation
11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
I4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door fully open, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH close operation
11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
I4-1 (BZR) - Body ground
W - Body ground
Slide door warning buzzer output
Slide door RH fully open → inside handle or outside handle pulled → slide door RH close operation
11 to 14 V → 11 to 14 V (approximately 0.8 seconds) → 11 to 14 V (approximately 0.4 seconds) → Below 1 V
I4-3 (DSV) - Body ground
P - Body ground
Slide door drive unit pulse sensor power supply
Ignition switch ON
11 to 14 V
I4-3 (DSV) - Body ground
P - Body ground
Slide door drive unit pulse sensor power supply
Ignition switch off
Below 1 V
I4-8 (MPX1) - Body ground
Y - Body ground
Handle switch input
Inside handle or outside handle not pulled → pulled
10 kΩ or higher → Below 1 Ω
I4-10 (CPSW) - Body ground
R - Body ground
Park/neutral position switch input
Ignition switch ON, shift lever P position → except P position
11 to 14 V → Below 1 V
I4-12 (RACT) - Body ground
R-B - Body ground
Slide door lock release motor drive output
Slide door RH fully close, auto slide door control switch assembly off → on or key's slide door RH switch pushed → slide door RH open operation → slide door RH fully open
Below 1 V → 11 to 14 V → Below 1 V
I4-14 (OS) - Body ground
G - Body ground
Power slide door sensor assembly input
Power slide door sensor assembly pushed → not pushed
Approximately below 100Ω → Approximately below 1k Ω
I4-15 (PKB) - Body ground
B - Body ground
Parking brake switch input
Parking brake lever pulled → not pulled
10 kΩ or higher → Below 1 Ω
I4-16 (DSW) - Body ground
Y - Body ground
Auto slide door control switch assembly input
Auto slide door control switch assembly off → on
Below 1 Ω → 10 kΩ or higher
I4-17 (MSW) - Body ground
V - Body ground
Auto slide door main switch input
Auto slide door main switch off → on
Below 1 Ω → 10 kΩ or higher
I4-20 (MPX2) - Body ground
L - Body ground
Handle switch input
Inside handle or outside handle not pulled → pulled
Below 1 Ω → 10 kΩ or higher
I4-22 (DLSW) - Body ground
GR - Body ground
Door unlock position switch input
Slide door RH fully open, slide door RH unlock → lock
Below 1 Ω → 10 kΩ or higher
I4-23 (DS2) - Body ground
B - Body ground
Slide door drive unit pulse sensor input
Slide door RH fully close → slide door RH open operation → slide door RH fully open → slide door RH close operation → slide door RH fully close
Below 1 V → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → 11 to 14 V (slide door fully open) → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → Below 1 V
I4-24 (DS1) - Body ground
LG - Body ground
Slide door drive unit pulse sensor input
Slide door RH fully close → slide door open operation → slide door RH fully open → slide door RH close operation → slide door RH fully close
Below 1 V → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → 11 to 14 V (slide door RH fully open) → Alternating 11 to 14 V and below 1 V (slide door RH in operation) → Below 1 V
| CHECK DOOR OPENING RELAY (for LH Side) |
Disconnect the p2 door opening relay connector.

Measure the resistance and voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
p2-2 (E) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
p2-6 (L) - Body ground
W - Body ground
Power supply
Always
11 to 14 V
p2-10 (E) - Body ground
BR - Body ground
Ground
Always
Below 1 Ω
Reconnect the p2 door opening relay connector.
Measure the voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
p2-1 (L) - p2-10 (E)
W - BR
Slide door lock release motor output
Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
Below 1 V → Below 1 V → Below 1 V → 11 to 14 V
p2-3 (UL1) - p2-10 (E)
R - BR
Slide door lock release motor output
Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
p2-5 (SIG) - p2-10 (E)
Y - BR
Release position switch output
Slide door fully open or closed → Slide door in opening operation or closing operation
11 to 14 V → Below 1 V → 11 to 14 V
p2-12 (P/W) - p2-10 (E)
L - BR
Initial position switch output
Slide door fully open or closed → Not completely open or closed
Below 1 V → 11 to 14 V → Below 1 V
| CHECK DOOR OPENING RELAY (for RH Side, w/ Power Slide Door) |
Disconnect the f2 door opening relay connector.

Measure the resistance and voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
f2-2 (E) - Body ground
W - Body ground
Ground
Always
Below 1 Ω
f2-6 (B) - Body ground
B - Body ground
Power supply
Always
11 to 14 V
f2-10 (MSE) - Body ground
BR - Body ground
Ground
Always
Below 1 Ω
Reconnect the f2 door opening relay connector.
Measure the voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
f2-1 (DC-) - f2-10 (MSE)
R - BR
Slide door lock release motor output
Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
Below 1 V → Below 1 V → Below 1 V → 11 to 14 V
f2-3 (DC+) - f2-10 (MSE)
B - BR
Slide door lock release motor output
Slide door lock fully closed → auto slide door control switch assembly on → Slide door lock releasing operation → Slide door lock fully released
Below 1 V → Below 1 V → 11 to 14 V → Below 1 V
f2-5 (HSW) - f2-10 (MSE)
Y - BR
Release position switch output
Slide door fully open or closed → Slide door in opening operation or closing operation
11 to 14 V → Below 1 V → 11 to 14 V
f2-12 (POS) - f2-10 (MSE)
L - BR
Initial position switch output
Slide door fully open or closed → Not completely open or closed
Below 1 V → 11 to 14 V → Below 1 V