2014-2019 Hiace · Service Manual BODY

DTC CHECK / CLEAR

Troubleshooting · Vehicles built from Oct 2014


1.VEHICLE INITIAL SETTING
    1. Stop the engine.
    2. Prepare the vehicle by making sure these slide operational conditions are met.
      1. Battery voltage is 11 V or more.
      2. The power slide door main switch is ON.
      3. The slide door lock is unlocked (the position switch is ON).
      4. The shift lever is in the P position.
    3. Fully close the slide door.
NEXT

2.SELF-DIAGNOSTIC MODE 1

    1. B163000E01
      Enter self-diagnostic mode 1.
      1. Turn OFF the power slide door main switch.
      2. Turn the ignition switch ON.
      3. Within 10 seconds, push the auto slide door control switch 10 times.
      4. Check that the buzzer sounds (see buzzer pattern 1).
      5. Within 3 seconds, turn ON the power slide door main switch.
      6. Check that the buzzer sounds (see buzzer pattern 2) and that the system enters self-diagnostic mode 1.
    2. Start the inspection.

      NOTICE:
      If the slide door operational conditions are not followed exactly, the system will change from self-diagnostic mode to normal operation mode.

      1. Push the auto slide door control switch assembly and fully open the slide door.
      2. Pull the inside door handle, and fully close the slide door.

        NOTICE:
        If the outside door handle is operated during this inspection, a self-diagnostic code may be output when the system enters self-diagnostic mode 2, regardless of the status (normal/malfunctioning) of the slide door.

      3. Perform the operations described in the table below.
      4. When changes in the input signals are detected, check that the buzzer emits a sound for 0.5 seconds. If the buzzer does not sound, proceed to the relevant troubleshooting page in accordance with the table.

        Target Items
        Inspection Operations
        Proceed to
        Shift lever (Park/neutral position switch)
        P position ←→ Expect P
        (Release shift lock before inspection)
        A
        Vehicle speed
        Less than 3 km/h (1 mph) ←→ 3 km/h (1 mph) or more
        B
        Slide door lock remote control assembly LH (door lock switch)
        ON ←→ OFF
        C
        Slide door lock remote control assembly RH (door lock switch) (for RH Side, w/ Power Slide Door)
        ON ←→ OFF
        D
        1. Power slide door sensor assembly
        2. Power slide door sensor assembly RH (for RH Side, w/ Power Slide Door)
        ON ←→ OFF
        E

    HINT:
    When necessary to return to the normal operation mode, go to step 5.


A.

B.

C.

D.

E.
NEXT

3.SELF-DIAGNOSTIC MODE 2

    1. B163001E02
      Change from self-diagnostic mode 1 to self-diagnostic mode 2.
      1. After the system has changed to self-diagnostic mode 1, press the auto slide door control switch assembly for less than 0.5 seconds.
      2. If the buzzer sounds twice, the system has successfully entered self-diagnostic mode 2.
    2. Start the inspection.

      1. Check that codes that have been detected during self-diagnostic mode 1 are output using these buzzer patterns.

        B163002E01

        Next step
        Proceed to
        Normal operation mode
        A
        Self-diagnostic mode 3
        B

        NOTICE:
        If the system returns to normal operation mode from self-diagnostic mode, the codes saved in its memory will be erased. When necessary, change to self-diagnostic mode 3 and perform confirmation before returning to normal operation mode.


A.
B

4.SELF-DIAGNOSTIC MODE 3

    1. B163001E01
      Change from self-diagnostic mode 2 to self-diagnostic mode 3.
      1. After the system has changed to self-diagnostic mode 2, press the auto slide door control switch assembly for less than 0.5 seconds.
      2. If the buzzer sounds twice, the system has successfully entered self-diagnostic mode 3.
    2. Start the inspection.
      1. Check the codes that were recorded in memory when a malfunction was detected in past operations through buzzer patterns.

        HINT:
        Codes are output in the same way as in self-diagnostic mode 2.

    3. Change from self-diagnostic mode 3 to normal operation mode.

      NOTICE:
      If the system returns to normal operation mode from self-diagnostic mode, all the codes saved in its memory will be erased.

      HINT:
      When one of the following conditions is met, the buzzer sounds twice and changes to normal operation mode.

      1. The ignition switch is turned OFF.
      2. The power slide door main switch is turned OFF.
      3. The auto slide door control switch assembly is pushed for less than 0.5 seconds.

END.
5.CHANGE FROM SELF-DIAGNOSTIC MODE 1 TO NORMAL OPERATION MODE
    1. The system changes from self-diagnostic mode 1 to normal operation mode when either of the following conditions is met:
      1. The ignition switch is turned OFF.
      2. The power slide door main switch is turned OFF.

END.
6.CHANGE FROM SELF-DIAGNOSTIC MODE 2 TO NORMAL OPERATION MODE
    1. The system changes from self-diagnostic mode 2 to normal operation mode when either of the following conditions is met:

      NOTICE:
      If the system returns to normal operation mode from self-diagnostic mode, all the codes saved in its memory will be erased.

      1. The ignition switch is turned OFF.
      2. The power slide door main switch is turned OFF.
END

← DIAGNOSIS SYSTEM (from Oct 2014)DIAGNOSTIC TROUBLE CODE CHART (Oct 2014 – Dec 2014) →