2014-2019 Hiace · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1413 Evaporator Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built Apr 2016 – Dec 2016

Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017

DESCRIPTION

The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
DTC Code
DTC Detection Condition
Trouble Area
B1413
An open or short in the No. 1 cooler thermistor circuit.
  1. No. 1 cooler thermistor
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM

E140288E50

INSPECTION PROCEDURE


1. READ VALUE USING GTS (NO. 1 COOLER THERMISTOR)
  1. Use the Data List to check if the No. 1 cooler thermistor is functioning properly (Click here).

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Evaporator Fin Thermistor
    No. 1 cooler thermistor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    Open in the circuit: -29.7°C (-21.46°F).
    Short in the circuit: 59.55°C (139.19°F).

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table)
    A
    OK (When troubleshooting according to the DTC)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
Go to step 2
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

2. INSPECT NO. 1 COOLER THERMISTOR
  1. Remove the No. 1 cooler thermistor.

  1. Inspect the No. 1 cooler thermistor (Click here).



NG
REPLACE NO. 1 COOLER THERMISTOR
OK


3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 COOLER THERMISTOR)
  1. Disconnect the H18 air conditioning harness assembly connector.

  1. Disconnect the H8 No. 1 cooler thermistor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H18-24 (TP) - H8-1
    Always
    Below 1 Ω
    H18-31 (SG) - H8-2
    Always
    Below 1 Ω
    H18-24 (TP) - Body ground
    Always
    10 kΩ or higher
    H18-31 (SG-1) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)


← B1413 Evaporator Temperature Sensor Circuit (Jan 2015 – Mar 2016)B1413 Evaporator Temperature Sensor Circuit (from Jan 2017) →