B1413 Evaporator Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Apr 2016 – Dec 2016
Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017
DESCRIPTION
The No. 1 cooler thermistor is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1413 |
An open or short in the No. 1 cooler thermistor circuit. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING GTS (NO. 1 COOLER THERMISTOR) |
Use the Data List to check if the No. 1 cooler thermistor is functioning properly (Click here).
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Evaporator Fin Thermistor
No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. INSPECT NO. 1 COOLER THERMISTOR |
Remove the No. 1 cooler thermistor.
Inspect the No. 1 cooler thermistor (Click here).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 COOLER THERMISTOR) |
Disconnect the H18 air conditioning harness assembly connector.
Disconnect the H8 No. 1 cooler thermistor connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
H18-24 (TP) - H8-1
Always
Below 1 Ω
H18-31 (SG) - H8-2
Always
Below 1 Ω
H18-24 (TP) - Body ground
Always
10 kΩ or higher
H18-31 (SG-1) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||