INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT INJECTOR ASSEMBLY |
 |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
20°C (68°F)
|
0.42 to 0.52 Ω
|