INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT NO. 2 VACUUM SWITCHING VALVE |
Measure the resistance between the terminals.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
33 to 39 Ω
Apply battery voltage across the terminals and check that air flows from E to F.

- Standard:
Inspection Condition
Air Flow
Battery voltage applied
Air flows
Battery voltage not applied
Air does not flow
| INSPECT NO. 2 EGR VALVE ASSEMBLY |
Check that the valve operates by applying a vacuum to the diaphragm.

- Standard:
Conditions
Operation
6.7 kPa (50.2 mmHg, 1.97 in.Hg) or higher
H side of valve closes
33.3 kPa (249.8 mmHg, 9.8 in.Hg) or less
C side of valve opens
Check that the indicator needle does not drop when a vacuum of 59 kPa (443 mmHg, 17.4 in.Hg) or higher is applied to the diaphragm chamber using a vacuum pump.