2014-2019 Hiace · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Jan 2017


INSPECT UREA INJECTOR SET
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    11.6 to 12.4 Ω

    If the result is not as specified, replace the urea injector set.

← REMOVAL (from Jan 2017)INSTALLATION (from Jan 2017) →