INSTALLATION
Removal / installation · Vehicles built from Jan 2017
| 1. INSTALL UREA PUMP |
Install a new gasket to the urea tank sub-assembly.
Install the urea pump to the urea tank sub-assembly as shown in the illustration.

Text in Illustration *a
Matchmark
Apply a co-rotation prevention check mark to the urea pump and urea tank sub-assembly.

Text in Illustration *a
Co-rotation Prevention Check Mark
- HINT:
- Perform this procedure when replacement of the urea pump is necessary.
Temporarily place the urea pump gauge retainer by aligning the rotational start point mark of the urea urea pump gauge retainer with the rotational start point mark of the urea tank sub-assembly while pressing the urea pump into the urea tank assembly.

Text in Illustration *a
Rotational Start Point Mark
(Urea Pump Gauge Retainer Side)
*b
Rotational Start Point Mark
(Urea Tank Sub-assembly Side)
Set 4 SSTs (claw sets) to the urea pump gauge retainer and temporarily install.

- SST
- 09808-14031
(09808-01080, 09808-01090, 09808-01100)
Text in Illustration *1
Urea Pump Gauge Retainer
*a
SST (Claw Set)
*b
Rib
*c
Cutout
*d
SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea pump Gauge Retainer)
While firmly pressing the claw of SST into rib of the urea pump gauge retainer, tighten the bolt.

Text in Illustration *1
Urea Pump Gauge Retainer
*a
SST (Claw Set)
*b
Press


Pinch


SST (Bolt)
Temporarily install SST (plate) to SST (claw set) with 4 SSTs (bolts).

Text in Illustration *a
SST (Plate)
*b
SST (Claw Set)


SST (Bolt)
Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.

Text in Illustration *a
Center of Urea Pump Gauge Retainer
*b
SST (Plate)
While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).

Text in Illustration *1
Urea Pump Gauge Retainer
*a
SST (Plate)
*b
SST (Claw Set)
*c
SST (Bolt)
*d
Rib


Press
While one person presses the urea pump into the urea tank sub-assembly, have another person firmly press the urea pump gauge retainer into the threads of the urea tank assembly and tighten approximately one and a half turns.

Text in Illustration *a
Tighten Start Position
*b
Co-rotation Prevention Check Mark
- NOTICE:
- Do not any tools other than SST, such as a screwdriver, etc.
- Do not excessive force when pressing down on SST, as the urea pump will place excessive force on urea pump gauge retainer and be difficult to remove, and parts may be damaged.
- Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.
- Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.
- Do not any tools other than SST, such as a screwdriver, etc.
While one person presses the urea pump into the urea tank sub-assembly have another person slowly tighten approximately half turns.

Text in Illustration *a
SST (Plate)
*b
Person in Change of Tightening
*c
Person in Charge of Supporting
Install SST (handle) to SST (plate).

- SST
- 09808-14031
(09808-01010, 09808-01020)
Text in Illustration *a
SST (Plate)
*b
SST (Handle)
*c
Tightening Complete Position
*d
Rotational Start Point Mark of Urea Pump Gauge Retainer
*e
Person in Charge of Tightening
*f
Person in Charge of Supporting


Tighten
While one person presses the urea pump onto the urea tank sub-assembly, have another person use SST (handle) and slowly tighten the urea pump gauge retainer until it reaches the tightening complete position.
| 2. INSTALL UREA TANK SUB-ASSEMBLY |