INSPECTION
Inspection · Vehicles built from Jan 2017
| INSPECT UREA PUMP |
Inspect the level sensor.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
14(LV1) - 6(ELV1)
Float position is upper
53.56 to 56.08 kΩ
Float position is lower
1.40 to 1.46 kΩ
Text in Illustration *a
Component without harness connected
(Urea Pump)
*b
Upper
*c
Lower
Inspect the tank heater.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
9(TH+) - 11(TH-)
25°C (77°F)
1.39 to 1.54 kΩ
Text in Illustration *a
Component without harness connected
(Urea Pump)
Inspect the temperature sensor.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1(TUW) - 2(ETUW)
20°C (68°F)
2.47 to 2.56 kΩ
30°C (86°F)
1.69 to 1.75 kΩ
Text in Illustration *a
Component without harness connected
(Urea Pump)
Inspect the pump motor.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
7(PHAA) - 8(PHAB)
20 to 30 °C (68 to 86°F)
0.35 to 0.43 Ω
7(PHAA) - 16(PHAC)
8(PHAB) - 16(PHAC)
7(PHAA) - 15(MGND)
Always
10 kΩ or higher
8(PHAB) - 15(MGND)
16(PHAC) - 15(MGND)
If the result is not as specified, replace the urea pump.Text in Illustration *a
Component without harness connected
(Urea Pump)