2014-2019 Hiace · Service Manual ENGINE

REMOVAL

Removal / installation · Vehicles built from Jan 2017


1. REMOVE FRONT BUMPER COVER
(Click here)

2. REMOVE UREA TANK PROTECTOR

  1. A396810
    Remove the 3 bolts and urea tank protector from the body.


3. DISCONNECT WIRE HARNESS

  1. A396811
    Disconnect the connector from the urea tube with heater assembly.

  1. Pull the tabs of the connector as shown in the illustration and disconnect the connector from the urea pump

  1. A396812
    Disconnect the 2 connectors from the front side wiring sub-assembly.

  1. A396813
    Detach the 2 clamps and disconnect the front side wiring sub-assembly from the urea tank sub-assembly.


4. DISCONNECT UREA TANK FILLER PIPE ASSEMBLY

  1. Disconnect the urea tank breather tube of the urea tank filler pipe assembly from the urea tank sub-assembly.

    NOTICE:
    Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before disconnection. Clean if necessary.


    1. A396814E01
      Detach the claw of the retainer of the urea tank breather tube connector, pull up the retainer and disconnect the urea tank breather tube connector from the urea tank sub-assembly.
      Text in Illustration 
      *a
      Retainer
      V100135
      Pull
      V100136
      Pull Out

      NOTICE:
      1. If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tank breather tube connector.
      2. Be sure to disconnect the urea tank breather tube connector by hand.
      3. Check for foreign matter in the urea tank sub-assembly and around the urea tank breather tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank breather tube connector.
      4. Put the urea tank sub-assembly and urea tank breather tube connector ends in plastic bags to prevent damage and foreign matter contamination.

  1. Disconnect the urea tank filler tube of the urea tank filler pipe assembly from the urea tank sub-assembly.

    NOTICE:
    Check for dirt or mud on the urea tank sub-assembly and around the urea tank filler tube connector before disconnection. Clean if necessary.


    1. A396816E01
      Detach the claw of the retainer of the urea tank filler tube connector, pull up the retainer and disconnect the urea tank filler tube connector from the urea tank sub-assembly.
      Text in Illustration 
      *a
      Retainer
      V100135
      Pull
      V100136
      Pull Out

      NOTICE:
      1. If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tank filler tube connector.
      2. Be sure to disconnect the urea tank filler tube connector by hand.
      3. Check for foreign matter in the urea tank sub-assembly and around the urea tank filler tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank filler tube connector.
      4. Put the tank sub-assembly and urea tank filler tube connector ends in plastic bags to prevent damage and foreign matter contamination.


5. DISCONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:
Check for dirt or mud on the urea pump and around the urea tube connector before disconnection. Clean if necessary.

  1. A396818
    Detach the clamp and disconnect the urea tube with the heater assembly from the urea tank sub-assembly.

  1. Remove the urea tube with heater assembly from the urea pump.

    1. A396819
      Detach the lock claw by lifting up the cover.
      Text in Illustration 
      V100135
      Lift Up

    2. A396820
      Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.
      Text in Illustration 
      V100135
      Pinch
      V100136
      Pull

      NOTICE:
      1. If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tube connector.
      2. Be sure to disconnect the urea tube connector by hand.
      3. Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.
      4. Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.


6. REMOVE UREA TANK SUB-ASSEMBLY

  1. A396822
    Loosen the clip and remove the 3 bolts and urea tank sub-assembly from the body.

  1. Remove the clip from the urea tank sub-assembly.


7. REMOVE UREA PUMP

  1. A396439E01
    Apply a co-rotation prevention check mark to the urea pump from the urea tank sub-assembly.
    Text in Illustration 
    *a
    Co-rotation Prevention Check Mark

    NOTICE:
    1. The urea tank sub-assembly cutout is attached to protrusion on the urea tube with heater assembly.
    2. If the urea pump and urea tank sub-assembly are not firmly attached and the urea pump gauge retainer is rotated, the urea pump will co-rotate and result in urea pump being damaged.
    3. Make sure to apply co-rotation prevention check mark to prevent the urea pump from co-rotating.

  1. A396440E01
    Set 4 SSTs (claw sets) to the urea pump gauge retainer and temporarily install.
    SST
    09808-14031   (09808-01080, 09808-01090, 09808-01100)
    Text in Illustration 
    *1
    Urea Pump gauge Retainer
    *a
    SST (Claw Set)
    *b
    Rib
    *c
    Cutout
    *d
    SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea Pump Gauge Retainer)

    NOTICE:
    1. Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.
    2. Do not place SST on the rotational start paint mark of the urea pump gauge retainer, otherwise SST (claw set) cannot be set correctly.

  1. A396441E01
    While firmly pressing the claw of SST into rib of the urea pump gauge retainer, tighten the bolt.
    Text in Illustration 
    *1
    Urea Pump Gauge Retainer
    *a
    SST (Claw Set)
    *b
    Press
    V100135
    Pinch
    V100136
    SST (Bolt)

  1. A396442E01
    Temporarily install SST (plate) to SST (claw set) with 4 SSTs (bolts).
    Text in Illustration 
    *a
    SST (Plate)
    *b
    SST (Claw Set)
    V100135
    SST (Bolt)

  1. A396443E01
    Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.
    Text in Illustration 
    *a
    Center of Urea Pump Gauge Retainer
    *b
    SST (Plate)

  1. A396444E01
    While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).
    Text in Illustration 
    *1
    Urea Pump Gauge Retainer
    *a
    SST (Plate)
    *b
    SST (Claw Set)
    *c
    SST (Bolt)
    *d
    Rib
    V100135
    Press

  1. A396445E01
    Install SST (handle) to SST (plate).
    SST
    09808-14031   (09808-01010, 09808-01020)
    Text in Illustration 
    *a
    SST (Plate)
    *b
    SST (Handle)
    *c
    SST (Claw Set)
    V100135
    Loosen

  1. Slowly loosen the urea pump gauge retainer by approximately 90°.

    NOTICE:
    1. Do not use any tools other than SST, such as screwdriver, etc.
    2. Do not excessive force when pressing down on SST, as urea tube with heater assembly will place excessive force on the urea pump gauge retainer and be difficult to remove, and parts may be damaged.
    3. Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.

  1. While on person slowly loosens the urea pump gauge retainer, have another person press down the rising urea pump, securely attach the protrusion of the urea pump to the groove of the urea tank sub-assembly, and then remove the urea pump gauge retainer while making sure that the urea pump is properly aligned.

    NOTICE:
    1. If the urea pump gauge retainer is turned while the urea pump and urea tank sub-assembly are not correctly aligned, urea pump will move with the urea pump gauge retainer, and the urea pump and urea tank sub-assembly may both be damaged.
    2. Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.


    A396446E01
    Text in Illustration 
    *a
    SST (Plate)
    *b
    SST (Handle)
    *c
    Person in Charge of Loosening
    *d
    Person in Charge of Supporting
    *e
    Co-rotation Prevention Check Mark
    -
    -

  1. A396447
    Remove the urea pump from the urea tank sub-assembly.

  1. A396448
    Remove the gasket from the urea tank sub-assembly.

← COMPONENTS (from Jan 2017)INSTALLATION (from Jan 2017) →