Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA TANK
RM35X0E _51 Engine / Hybrid System _079220 1GD-FTV EMISSION CONTROL _0384126 UREA TANK A

1GD-FTV EMISSION CONTROL  UREA TANK  REMOVAL  


PROCEDURE

Hide 51495 1.REMOVE TRANSMISSION UNDER COVER (w/ Cover)

a.
A443304

Detach the clip and remove the 6 bolts.


b.
A443305

Loosen the 3 nuts and remove the transmission under cover from the body.


Hide 51774B 2.REMOVE STEP PLATE COVER LH (w/ Cover)

a.
A443306

Detach the 3 clips and remove the 2 bolts.


b.
A443307

Loosen the 3 nuts and remove the step plate cover LH from the body.


Hide 77851A 3.REMOVE UREA TANK PROTECTOR

a.
A436286

Detach the clip.


b.
A436287

Detach the 2 claws and remove the urea tank protector from the urea tank sub-assembly.


Hide 82164 4.DISCONNECT FRAME WIRE

a.
A436289

Pull the tabs of the connector as shown in the illustration and disconnect the connector from the urea pump.


b.
A436291

Disconnect the connector from the urea tube with heater assembly.


c.
A436292

Detach the clamp and disconnect the frame wire from the urea tank sub-assembly.


Hide 77840A 5.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube with heater connector before disconnection. Clean if necessary.


a.

Remove the urea tube with heater assembly from the urea pump.

i.
A436293C01
0,0 0,0 false
V113147

Lift Up


Detach the lock claw by lifting up the cover.


ii.
A436295C01
0,0 0,0 false
V113147

Pinch
V113148

Pull


Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tube connector by hand.

·

Check for foreign matter in the urea pump and around the urea tube with heater connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube with heater connector.

·

Put the urea pump and urea tube with heater connector ends in plastic bags to prevent damage and foreign matter contamination.





b.
A436297

Detach the 2 clamps and disconnect the urea tube with heater assembly from the urea tank sub-assembly.


Hide 77852 6.REMOVE NO. 2 UREA TANK PROTECTOR

a.
A436298

Remove the 3 bolts and No. 2 urea tank protector from the urea tank sub-assembly.


Hide 77910 7.DISCONNECT UREA TANK FILLER PIPE ASSEMBLY

a.

Disconnect the urea tank filler tube of the urea tank filler pipe assembly from the urea tank sub-assembly.

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the urea tank filler tube connector before disconnection. Clean if necessary.


i.
A436299C01
0,0 0,0 false
V113147

Pull
V113148

Pull Out


Detach the claw of the retainer of the urea tank filler tube connector, pull up the retainer and disconnect the urea tank filler tube connector from the urea tank sub-assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tank filler tube connector.

·

Be sure to disconnect the urea tank filler tube connector by hand.

·

Check for foreign matter in the urea tank sub-assembly and around the urea tank filler tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank filler tube connector.

·

Put the tank sub-assembly and urea tank filler tube connector ends in plastic bags to prevent damage and foreign matter contamination.





b.

Disconnect the urea tank breather tube of the urea tank filler pipe assembly from the urea tank sub-assembly.

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before disconnection. Clean if necessary.


i.
A436301C01
0,0 0,0 false
V113147

Pull
V113148

Pull Out


Detach the claw of the retainer of the urea tank breather tube connector, pull up the retainer and disconnect the urea tank breather tube connector from the urea tank sub-assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tank breather tube connector.

·

Be sure to disconnect the urea tank breather tube connector by hand.

·

Check for foreign matter in the urea tank sub-assembly and around the urea tank breather tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank breather tube connector.

·

Put the urea tank sub-assembly and urea tank breather tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77801A 8.REMOVE UREA TANK SUB-ASSEMBLY

a.
A436304

Detach the 2 clips and remove the 3 bolts and urea tank sub-assembly from the body.