51495
1.REMOVE TRANSMISSION UNDER COVER (w/ Cover)
Detach the clip and remove the 6 bolts.
Loosen the 3 nuts and remove the transmission under cover from the body.
51774B
2.REMOVE STEP PLATE COVER LH (w/ Cover)
Detach the 3 clips and remove the 2 bolts.
Loosen the 3 nuts and remove the step plate cover LH from the body.
77851A
3.REMOVE UREA TANK PROTECTOR
Detach the clip.
Detach the 2 claws and remove the urea tank protector from the urea tank sub-assembly.
82164
4.DISCONNECT FRAME WIRE
Pull the tabs of the connector as shown in the illustration and disconnect the connector from the urea pump.
Disconnect the connector from the urea tube with heater assembly.
Detach the clamp and disconnect the frame wire from the urea tank sub-assembly.
77840A
5.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea pump and around the urea tube with heater connector before disconnection. Clean if necessary.
Remove the urea tube with heater assembly from the urea pump.
|
Lift Up |
Detach the lock claw by lifting up the cover.
|
Pinch |
|
Pull |
Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea pump and around the urea tube with heater connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube with heater connector.
Put the urea pump and urea tube with heater connector ends in plastic bags to prevent damage and foreign matter contamination.
Detach the 2 clamps and disconnect the urea tube with heater assembly from the urea tank sub-assembly.
77852
6.REMOVE NO. 2 UREA TANK PROTECTOR
Remove the 3 bolts and No. 2 urea tank protector from the urea tank sub-assembly.
77910
7.DISCONNECT UREA TANK FILLER PIPE ASSEMBLY
Disconnect the urea tank filler tube of the urea tank filler pipe assembly from the urea tank sub-assembly.
Check for dirt or mud on the urea tank sub-assembly and around the urea tank filler tube connector before disconnection. Clean if necessary.
|
Pull |
|
Pull Out |
Detach the claw of the retainer of the urea tank filler tube connector, pull up the retainer and disconnect the urea tank filler tube connector from the urea tank sub-assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tank filler tube connector.
Be sure to disconnect the urea tank filler tube connector by hand.
Check for foreign matter in the urea tank sub-assembly and around the urea tank filler tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank filler tube connector.
Put the tank sub-assembly and urea tank filler tube connector ends in plastic bags to prevent damage and foreign matter contamination.
Disconnect the urea tank breather tube of the urea tank filler pipe assembly from the urea tank sub-assembly.
Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before disconnection. Clean if necessary.
|
Pull |
|
Pull Out |
Detach the claw of the retainer of the urea tank breather tube connector, pull up the retainer and disconnect the urea tank breather tube connector from the urea tank sub-assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tank breather tube connector.
Be sure to disconnect the urea tank breather tube connector by hand.
Check for foreign matter in the urea tank sub-assembly and around the urea tank breather tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank breather tube connector.
Put the urea tank sub-assembly and urea tank breather tube connector ends in plastic bags to prevent damage and foreign matter contamination.
77801A
8.REMOVE UREA TANK SUB-ASSEMBLY
Detach the 2 clips and remove the 3 bolts and urea tank sub-assembly from the body.
77871A
9.REMOVE UREA PUMP