Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA TANK
RM35X0E _51 Engine / Hybrid System _079220 1GD-FTV EMISSION CONTROL _0384126 UREA TANK A

1GD-FTV EMISSION CONTROL  UREA TANK  INSTALLATION  


PROCEDURE

Hide 77801A 2.INSTALL UREA TANK SUB-ASSEMBLY

a.

Attach the 2 clips and install the urea tank sub-assembly to the body with the 3 bolts.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


Hide 77910 3.CONNECT UREA TANK FILLER PIPE ASSEMBLY

a.

Connect the urea tank breather tube of the urea tank filler pipe assembly to the urea tank sub-assembly.

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before connection. Clean if necessary.


HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tank breather tube and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tank breather tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).


iii.
A436302C01
0,0 0,0 false
V113147

Push
V113148

Push Down


Align the axis of the urea tank breather tube connector with the axis of the urea tank sub-assembly. Push the urea tank breather tube connector into the urea tank sub-assembly until the urea tank breather tube connector makes a" click" sound.


iv.

Push down the retainer.


v.

After connecting the urea tank sub-assembly and the urea tank breather tube connector, check that the urea tank sub-assembly and urea tank breather tube connector are securely connected by trying to pull them apart.



b.

Connect the urea tank filler tube of the urea tank filler pipe assembly to the urea tank sub-assembly.

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the urea tank filler tube connector before connection. Clean if necessary.


HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tank filler tube and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tank filler tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).


iii.
A436300C01
0,0 0,0 false
V113147

Push
V113148

Push Down


Align the axis of the urea tank filler tube connector with the axis of the urea tank sub-assembly. Push the urea tank filler tube connector into the urea tank sub-assembly until the urea tank filler tube connector makes a "click" sound.


iv.

Push down the retainer.


v.

After connecting the urea tank sub-assembly and the urea tank filler tube connector, check that the urea tank sub-assembly and urea tank filler tube connector are securely connected by trying to pull them apart.



Hide 77852 4.INSTALL NO. 2 UREA TANK PROTECTOR

a.

Install the No. 2 urea tank protector to the urea tank sub-assembly with the 3 bolts.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


Hide 77840A 5.CONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube connector before connection. Clean if necessary.


a.

Attach the 2 clamps and connect the urea tube with heater assembly to the urea tank sub-assembly.


b.

Install the urea tube with heater assembly to the urea pump.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).


iii.
A436296C01
0,0 0,0 false
V113147

Push


Align the axis of the urea tube connector with the axis of the urea pump. Push the urea tube connector into the urea pump until the urea tube connector makes a "click" sound.


iv.

After connecting the urea pump and the urea tube connector, check that the urea pump and urea tube connector are securely connected by trying to pull them apart.


v.
A436294C01
0,0 0,0 false
V113147

Push Down


Attach the lock claws to the urea tube connector by pushing down on the cover.



Hide 82164 6.CONNECT FRAME WIRE

a.

Attach the clamp and connect the frame wire to the urea tank sub-assembly.


b.

Connect the connector to the urea tube with heater assembly.


c.
A436290

Connect the connector to the urea pump and push the tub as shown in the illustration.


Hide 77851A 7.INSTALL UREA TANK PROTECTOR

a.

Attach the 2 claws and install the urea tank protector to the urea tank sub-assembly.


b.

Attach the clip.


Hide 51774B 8.INSTALL STEP PLATE COVER LH (w/ Cover)

a.

Install the step plate cover LH to the body and tighten the 3 nuts.


b.

Attach the 3 clips and install the 2 bolts.

Torque:
5.5 N*m (56 kgf*cm, 49 in.*lbf)


Hide 51495 9.INSTALL TRANSMISSION UNDER COVER (w/ Cover)

a.

Install the transmission under cover to the body and tighten the 3 nuts.


b.

Attach the clip and install the 6 bolts.

Torque:
5.5 N*m (56 kgf*cm, 49 in.*lbf)