77871A
1.INSTALL UREA PUMP
77801A
2.INSTALL UREA TANK SUB-ASSEMBLY
Attach the 2 clips and install the urea tank sub-assembly to the body with the 3 bolts.
77910
3.CONNECT UREA TANK FILLER PIPE ASSEMBLY
Connect the urea tank breather tube of the urea tank filler pipe assembly to the urea tank sub-assembly.
Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before connection. Clean if necessary.
If there is any solidified urea solution (white solids) on the connection areas of the urea tank breather tube and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tank breather tube connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).
|
Push |
|
Push Down |
Align the axis of the urea tank breather tube connector with the axis of the urea tank sub-assembly. Push the urea tank breather tube connector into the urea tank sub-assembly until the urea tank breather tube connector makes a" click" sound.
Push down the retainer.
After connecting the urea tank sub-assembly and the urea tank breather tube connector, check that the urea tank sub-assembly and urea tank breather tube connector are securely connected by trying to pull them apart.
Connect the urea tank filler tube of the urea tank filler pipe assembly to the urea tank sub-assembly.
Check for dirt or mud on the urea tank sub-assembly and around the urea tank filler tube connector before connection. Clean if necessary.
If there is any solidified urea solution (white solids) on the connection areas of the urea tank filler tube and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tank filler tube connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).
|
Push |
|
Push Down |
Align the axis of the urea tank filler tube connector with the axis of the urea tank sub-assembly. Push the urea tank filler tube connector into the urea tank sub-assembly until the urea tank filler tube connector makes a "click" sound.
Push down the retainer.
After connecting the urea tank sub-assembly and the urea tank filler tube connector, check that the urea tank sub-assembly and urea tank filler tube connector are securely connected by trying to pull them apart.
77852
4.INSTALL NO. 2 UREA TANK PROTECTOR
Install the No. 2 urea tank protector to the urea tank sub-assembly with the 3 bolts.
77840A
5.CONNECT UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea pump and around the urea tube connector before connection. Clean if necessary.
Attach the 2 clamps and connect the urea tube with heater assembly to the urea tank sub-assembly.
Install the urea tube with heater assembly to the urea pump.
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).
|
Push |
Align the axis of the urea tube connector with the axis of the urea pump. Push the urea tube connector into the urea pump until the urea tube connector makes a "click" sound.
After connecting the urea pump and the urea tube connector, check that the urea pump and urea tube connector are securely connected by trying to pull them apart.
|
Push Down |
Attach the lock claws to the urea tube connector by pushing down on the cover.
82164
6.CONNECT FRAME WIRE
Attach the clamp and connect the frame wire to the urea tank sub-assembly.
Connect the connector to the urea tube with heater assembly.
Connect the connector to the urea pump and push the tub as shown in the illustration.
77851A
7.INSTALL UREA TANK PROTECTOR
Attach the 2 claws and install the urea tank protector to the urea tank sub-assembly.
Attach the clip.
51774B
8.INSTALL STEP PLATE COVER LH (w/ Cover)
Install the step plate cover LH to the body and tighten the 3 nuts.
Attach the 3 clips and install the 2 bolts.
51495
9.INSTALL TRANSMISSION UNDER COVER (w/ Cover)
Install the transmission under cover to the body and tighten the 3 nuts.
Attach the clip and install the 6 bolts.