Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › 2019.02–2019.06
RM35X0E _58 Vehicle Interior _079316 HEATING / AIR CONDITIONING _0386651 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1497  Communication Malfunction (Bus Ic)  


DESCRIPTION

The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1497 Communication Malfunction (Bus Ic)
·

Diagnosis condition: None

·

Malfunction status: Error or open in communication line between air conditioning amplifier assembly and servo motor


·

Air conditioning harness assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

No. 1 blower damper servo sub-assembly

·

Air conditioning amplifier assembly


Memorized

WIRING DIAGRAM

E414332E01
5.042,0.708 5.813,0.906 0.771,0.198 10 false BUS 5.042,1.094 5.813,1.292 0.771,0.198 10 false BUSB 5.052,1.49 5.823,1.688 0.771,0.198 10 false BUSG 4.76,0.677 5.01,0.875 0.25,0.198 10 false 3 4.76,1.104 5.01,1.302 0.25,0.198 10 false 4 4.771,1.479 5.021,1.677 0.25,0.198 10 false 2 1.385,3.677 1.823,3.865 0.438,0.188 10 false Mode 0.771,4.896 2.688,5.563 1.917,0.667 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.875,7.5 2.573,8 1.698,0.5 10 false No. 1 Blower Damper Servo Sub-assembly 3.156,7.438 4.698,7.875 1.542,0.438 10 false Air Conditioning Harness Assembly 4.729,8.083 5.5,8.281 0.771,0.198 10 false t2 4.719,8.25 6.99,8.5 2.271,0.25 10 false Air Conditioning Amplifier Assembly 0.885,8.563 3.26,8.823 2.375,0.26 10 false : LIN Communication Line 6.021,0.823 6.792,1.021 0.771,0.198 10 false IC 6.333,0.938 7.104,1.135 0.771,0.198 10 false +B 1.26,1.438 1.771,1.646 0.51,0.208 10 false Air Mix

PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse Min.: 128
Max.: 383
Operates between 165 to 257 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse Min.: 128
Max.: 383
Operates between 256 to 348 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 220 to 256 pulses
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Outlet Servo Pulse (D)
50004 121 26
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet Damper Targ Pulse
50004 121 27
OK:

Damper servo motor is operated.



f.

Check the operation by referring to the table below.


Result:
Result Proceed to
All damper servo motors are not operated A
Any damper servo motor is not operated B
All damper servo motors are operated C



A

2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (POWER SOURCE CIRCUIT)

B

C

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (POWER SOURCE CIRCUIT)
a.
E407116C03
2.344,1.792 2.844,2.042 0.5,0.25 1.865,0.698 1.969,0.104 1.969,0.104 2.219,0.104 true 1.99,0.708 2.375,0.292 2.375,0.292 2.625,0.292 true 1.729,0.688 1.479,0.271 1.479,0.271 1.198,0.271 true 0.094,0.052 0.406,0.25 0.313,0.198 10 false *a 2.51,1.833 2.823,2.031 0.313,0.198 10 false t2 2.292,0.021 2.604,0.219 0.313,0.198 10 false BUS 2.677,0.208 3.208,0.417 0.531,0.208 10 false BUSG 0.396,3.938 0.927,4.146 0.531,0.208 10 false GND 0.75,0.188 1.281,0.396 0.531,0.208 10 false BUSB
*a Component without harness connected
(Air Conditioning Amplifier Assembly)


Disconnect the air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (BUSG) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
2 (BUSG) - 4 (BUSB) Always 11 to 14 V



d.

Using an oscilloscope, check the waveform.

Item Content
Tester Connection 2 (BUSG) - 3 (BUS)
Tool Setting 2 V/DIV., 20 μs/DIV.
Condition Ignition switch ON

OK:

The waveform displays properly.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG