Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Exhaust Gas Temperature Sensor for EGR) › 2019.06–2021.07
RM35X0E _51 Engine / Hybrid System _078856 1GD-FTV ENGINE CONTROL _0395991 ECD SYSTEM(w/ Exhaust Gas Temperature Sensor for EGR) J

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Exhaust Gas Temperature Sensor for EGR)  After Treatment Control System  


CAUTION / NOTICE / HINT

NOTICE:

After replacing the exhaust manifold converter sub-assembly (DPF catalyst), clear the thermal deterioration data stored in the ECM.

Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Exhaust Gas Temperature Sensor for EGR)>INITIALIZATION


PROCEDURE

1.TAKE SNAPSHOT DURING IDLING AND 4000 RPM (PROCEDURE 1)
a.

Connect the GTS to the DLC3.


b.

Start the engine and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and Transmission / Data List / Diesel Exhaust.


d.

Take a snapshot of the following Data List items.

HINT:
·

A snapshot can be used to compare vehicle data from the time of the malfunction to normal data and is very useful for troubleshooting. The data in the list below is that of a normal vehicle, but as the data varies between individual vehicles, this data should only be used for reference.

·

Check the Data List at idling and at 4000 rpm with no load after the engine is warmed up.




Result:
Proceed to
NEXT



NEXT

2.READ VALUE USING GTS (CATALYST DIFFERENTIAL PRESSURE BANK 1)
2.READ VALUE USING GTS (CATALYST DIFFERENTIAL PRESSURE BANK 1)
a.

Check Catalyst Differential Pressure Bank 1 in the snapshot taken in procedure 1 when the engine was running at 4000 rpm with no load.

Result:
Result Proceed to
Catalyst Differential Pressure Bank 1 is more than 0.27 A
Except above B




A

3.REPLACE EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY

B

5.PERFORM PM FORCED REGENERATION
3.REPLACE EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY
a.

Replace the exhaust manifold converter sub-assembly.

Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>MONOLITHIC CONVERTER (w/ DPF)>REMOVAL


Result:
Proceed to
NEXT



NEXT

4.PERFORM CATALYST DETERIORATION LEARNING VALUE AND DPF DEPOSITION VALUE CLEAR FUNCTION
4.PERFORM CATALYST DETERIORATION LEARNING VALUE AND DPF DEPOSITION VALUE CLEAR FUNCTION
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and Transmission / Utility / Catalyst Deterioration Learning Value Clear.

Powertrain > Engine and Transmission > Utility
Tester Display
Catalyst Deterioration Learning Value Clear
50005 456 4568

d.

Press "Next".


e.

Press "Exit".


f.

Enter the menu options in this order: Powertrain / Engine and Transmission / Utility / DPF Deposition Value Clear.

Powertrain > Engine and Transmission > Utility
Tester Display
DPF Deposition Value Clear
50005 456 4574

g.

Press "Next".


h.

Press "Exit".


Result:
Proceed to
NEXT



NEXT

5.PERFORM PM FORCED REGENERATION
5.PERFORM PM FORCED REGENERATION
a.

Turn the engine switch on (IG).


b.

Turn the engine switch off and wait for 30 seconds or more.


c.

Turn the engine switch on (IG) and wait for 10 seconds or more.


d.

Connect the GTS to the DLC3.


e.

Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.


f.

Maintain the maximum possible engine speed under no load for 10 seconds to blow out all soot from inside the exhaust pipe.

HINT:
·

If only a low engine speed is continuously maintained, soot may accumulate at the end of the catalyst.

·

When soot accumulates at the end of the catalyst, it may not be possible to perform PM forced regeneration control normally.




g.

Enter the following menus: Powertrain / Engine and Transmission / Utility / PM Regenerate Mode

Powertrain > Engine and Transmission > Utility
Tester Display
PM Regenerate Mode
50005 456 4576

h.

Enter PM Regenerate Mode.

CAUTION:

Be careful of the exhaust pipes and surrounding areas, as they become extremely hot when performing PM forced regeneration.



i.

After 10 minutes have passed with the Coolant Temperature at 80°C (176°F) or higher during PM regeneration, check the value of Exhaust Temperature B1S2.

Powertrain > Engine and Transmission > Data List
Tester Display
Coolant Temperature
Exhaust Temperature B1S2
50003 456 237,340
HINT:
·

PM forced regeneration takes 15 to 40 minutes to finish.

·

The time it takes to complete PM forced regeneration changes depending on "PM Accumulation Ratio Bank 1" and the vehicle operating conditions.

·

If the value of "Catalyst Differential Pressure Bank 1" increases too much during the PM forced regeneration, the failsafe function activates and PM forced regeneration is stopped.

·

Perform PM forced regeneration control until the display on the multi-information display turns off.

·

If actions such as depressing the accelerator pedal or operating the DPF switch, etc. are performed during PM forced regeneration, PM forced regeneration stops. If PM forced regeneration stops, it is necessary to perform it again.

·

PM forced regeneration control is not complete until the display on the multi-information display turns off.




Result:
Result Proceed to
Exhaust Temperature B1S2 does not reach 500°C (932°F)* A
Exhaust Temperature B1S2 reaches 500°C (932°F) or higher B


HINT:

*: If Exhaust Temperature B1S2 is not 500°C (932°F) or more, the exhaust fuel addition injector assembly may be blocked by accumulated deposits in the No. 1 injector holder.



B

END

A

REPLACE EXHAUST FUEL ADDITION INJECTOR ASSEMBLY AND NO. 1 INJECTOR HOLDER

Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>EXHAUST FUEL ADDITION INJECTOR>REMOVAL

HINT:

If there is no malfunction in the electrical system, Exhaust Temperature B1S2 is 500°C (932°F) or less even though fuel is injected, and white smoke is not emitted, replace the exhaust fuel addition injector assembly together with the No. 1 injector holder.