| B1411
|
Room Temperature Sensor Circuit
|
·
Diagnosis condition: Ambient temperature is -30°C (-22°F) or more
·
Malfunction status: Open or short in room temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1412
|
Ambient Temperature Sensor Circuit
|
·
Diagnosis condition: None
·
Malfunction status: Open or short in ambient temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1413
|
Evaporator Temperature Sensor Circuit
|
·
Diagnosis condition: None
·
Malfunction status: Open or short in evaporator temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1417
|
Evaporator Temperature Circuit
|
·
Diagnosis condition: None
·
Malfunction status: Open or short in evaporator temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1419/19
|
Rear Room Temperature Sensor Circuit
|
·
Diagnosis condition: Ambient temperature is -30°C (-22°F) or more
·
Malfunction status: Open or short in room temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1422
|
Compressor Lock Sensor Circuit
|
Open or short in A/C lock sensor circuit
·
Diagnosis condition: Cooler compressor assembly operating
·
Malfunction status: Open or short in cooler compressor circuit
·
Detection time: None (Present malfunction), continuously for 3 seconds or more (Past malfunction)
|
|
| B1423
|
Pressure Sensor Circuit
|
·
Diagnosis condition: Ignition switch ON
·
Malfunction Status: Refrigerant pressure signal malfunction
·
Detection time: Continuously for 4 seconds or more (Present malfunction)
|
|
| B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
·
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (air mix) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
·
Diagnosis condition: During No. 1 blower damper servo sub-assembly operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
·
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (mode) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1447
|
Air Mix Damper Control Servo Motor Circuit (Rear)
|
·
Diagnosis condition: During No. 1 rear cooling unit damper servo sub-assembly (mode) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
·
Diagnosis condition: During No. 2 rear cooling unit damper servo sub-assembly (mode) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1497
|
Communication Malfunction (Bus Ic)
|
·
Diagnosis condition: None
·
Malfunction status: Error or open in communication line between air conditioning amplifier assembly and servo motor
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
·
Diagnosis condition: Ignition switch ON
·
Malfunction status: Lost communication with air conditioning control assembly
·
Detection time: Continuously for 10 seconds or more
|
|
| B14B3
|
Lost Communication with Rear Panel LIN
|
·
Diagnosis condition: Ignition switch ON
·
Malfunction status: Lost communication with integration control and panel assembly
·
Detection time: Continuously for 10 seconds or more
|
|
| B14B8
|
Refrigerant Shortage
|
·
Diagnosis condition: The amount of refrigerant is judged to be insufficient in normal operation
·
Malfunction status: When following condition is detected in refrigerant shortage check in normal operation; Amount of refrigerant is insufficient
·
Detection time: During air conditioning system operation for 10 minutes or more
|
|
| B14B9
|
Open in Ion Generator Circuit
|
·
Diagnosis condition: Ignition switch ON, blower switch on and "nanoe" on
·
Malfunction status: Open in No. 1 ion generator sub-assembly circuit
·
Detection time: None (Present malfunction), continuously for 12 seconds or more (Past malfunction)
|
|
| B14BA
|
Open in Rear Ion Generator Circuit
|
·
Diagnosis condition: Ignition switch ON, blower switch on and "nanoe" on
·
Malfunction status: Open in No. 2 ion generator sub-assembly circuit
·
Detection time: None (Present malfunction), continuously for 12 seconds or more (Past malfunction)
|
|
| U0100
|
Lost Communication with ECM / PCM "A"
|
No communication with ECM
|
|
| U0142
|
Lost Communication with Body Control Module "B"
|
No communication with main body ECU (multiplex network body ECU)
|
|
| U0155
|
Lost Communication with Instrument Panel Cluster (IPC) Control Module
|
No communication with combination meter assembly
|
|