Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (for Water Cooled Type Intercooler) › from 2020.05
RM35X0E _51 Engine / Hybrid System _078856 1GD-FTV ENGINE CONTROL _0412266 ECD SYSTEM(for Water Cooled Type Intercooler) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(for Water Cooled Type Intercooler)  P023A15  Charge Air Cooler Coolant Pump Control Circuit Short to Battery or Open  


DESCRIPTION

Refer to DTC P023A12.

Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (for Water Cooled Type Intercooler)>P023A12

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P023A15 Charge Air Cooler Coolant Pump Control Circuit Short to Battery or Open When the electric water pump assembly speed is below 10 rpm, the IWPI input is continuously equal to or more than the judgment value for 14.5 seconds or more.
(1 trip detection logic)
·

Open or short in electric water pump assembly circuit

·

Electric water pump assembly

·

E/G W/PMP relay

·

ECM


Comes on DTC stored SAE Code: P2CA1

Related Data List
DTC No. Data List
P023A15
·

Intercooler Water Pump Speed

·

Intercooler Water Pump



MONITOR DESCRIPTION

The ECM calculates the speed of the electric water pump assembly by using the rotational duty signal (IWPI) sent from the electric water pump assembly.

A 4 Hz duty signal (IWPI) is output even when the pump is stopped. The ECM then converts the electric water pump assembly rotational duty signal (IWPI) into the speed and checks that it is 160 rpm when the pump is stopped.

If the electric water pump assembly speed is below 10 rpm and the IWPI input level is high, this DTC is stored.

CONFIRMATION DRIVING PATTERN

DTC No. DTC Detection Drive Pattern
P023A15 After fully warming up, increase and maintain the engine speed so that the intercooler water pump duty ratio is 30% or more for 3 seconds or longer.

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses for circuits related to this system before performing the following procedure.



HINT:

Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (CONTROL THE INTERCOOLER WATER PUMP)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine / Active Test / Control the Intercooler Water Pump.


d.

Perform the Active Test. Check that the electric water pump assembly is operating (vibrating).

Powertrain > Engine > Active Test
Tester Display
Control the Intercooler Water Pump
50004 372 9
OK:

The electric water pump assembly is operating (vibrating).


HINT:

Use a sound scope if the operation is difficult to check.



Result:
Proceed to
OK
NG



OK

2.CHECK ECM (IWPI VOLTAGE)

NG

4.CHECK HARNESS AND CONNECTOR (ELECTRIC WATER PUMP ASSEMBLY - BODY GROUND)
2.CHECK ECM (IWPI VOLTAGE)
a.
A449468C10
1.49,0.385 1.927,0.667 0.438,0.281 1.167,1.635 1.583,1.219 true 1.604,0.438 2.115,0.656 0.51,0.219 11 false D1 0.052,0.042 0.365,0.24 0.313,0.198 10 false *a 0.906,1.677 1.365,1.875 0.458,0.198 10 false NWP
*a Front view of wire harness connector
(to Electric Water Pump Assembly)


Disconnect the electric water pump assembly connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
D1-2 (NWP) - Body ground Ignition switch ON 11 to 14 V
D1-2 (NWP) - Body ground Ignition switch off Below 1 V



Result:
Proceed to
OK
NG



OK

NG

3.CHECK HARNESS AND CONNECTOR (ELECTRIC WATER PUMP ASSEMBLY - ECM)
3.CHECK HARNESS AND CONNECTOR (ELECTRIC WATER PUMP ASSEMBLY - ECM)
a.

Disconnect the electric water pump assembly connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D1-2 (NWP) - E6-14 (IWPI) Always Below 1 Ω
D1-2 (NWP) or E6-14 (IWPI) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

4.CHECK HARNESS AND CONNECTOR (ELECTRIC WATER PUMP ASSEMBLY - BODY GROUND)
a.

Disconnect the electric water pump assembly connector.


b.
A449468C12
1.49,0.365 1.927,0.646 0.438,0.281 1,1.688 1.365,1.198 true 1.635,0.427 2.146,0.646 0.51,0.219 11 false D1 0.052,0.042 0.365,0.24 0.313,0.198 10 false *a 0.729,1.698 1.396,1.906 0.667,0.208 10 false GND
*a Front view of wire harness connector
(to Electric Water Pump Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D1-1 (GND) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

5.CHECK TERMINAL VOLTAGE (POWER SOURCE OF ELECTRIC WATER PUMP ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK TERMINAL VOLTAGE (POWER SOURCE OF ELECTRIC WATER PUMP ASSEMBLY)
a.
A449468C13
1.49,0.365 1.927,0.646 0.438,0.281 2.375,1.677 2.073,1.188 true 1.625,0.427 2.135,0.646 0.51,0.219 11 false D1 0.052,0.042 0.365,0.24 0.313,0.198 10 false *a 2.448,1.698 3.115,1.906 0.667,0.208 10 false +BWP
*a Front view of wire harness connector
(to Electric Water Pump Assembly)


Disconnect the electric water pump assembly connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
D1-4 (+BWP) - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

NG

6.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - ELECTRIC WATER PUMP ASSEMBLY)
6.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - ELECTRIC WATER PUMP ASSEMBLY)
a.

Remove the No. 1 integration relay from the No. 1 engine room relay block and junction block assembly.


b.

Disconnect the electric water pump assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1E-11 - D1-4 (+BWP) Always Below 1 Ω
1E-11 or D1-4 (+BWP) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

7.INSPECT NO. 1 INTEGRATION RELAY (E/G W/PMP RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.INSPECT NO. 1 INTEGRATION RELAY (E/G W/PMP RELAY)
a.

Inspect the No. 1 integration relay. (E/G W/PMP relay).

Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION


Result:
Proceed to
OK
NG



OK

8.INSPECT HARNESS AND CONNECTOR

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

8.INSPECT HARNESS AND CONNECTOR
a.

Remove the No. 1 integration relay from the No. 1 engine room relay block and junction block assembly.


b.

Remove the EFI MAIN relay from the No. 1 engine room relay block and junction block assembly.


c.

Measure the resistance according to the value(s) in the table below.


Standard Resistance:
Tester Connection Condition Specified Condition
1E-8 - EFI MAIN relay terminal 5 Always Below 1 Ω
1E-8 or EFI MAIN relay terminal 5 - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR