2007-2013 Highlander Kluger · Service Manual BODY ELECTRICAL

Voice Recognition Difficulty

Circuit diagnosis · Vehicles built from Jul 2012

Versions by build date: Jul 2010 – Jun 2012 from Jul 2012

INSPECTION PROCEDURE


1. CHECK CONDITION
  1. Check if the system voice recognition level is low when recognizing a particular voice.

    Result:
    Result
    Proceed to
    System voice recognition level is low with any voice.
    A
    System voice recognition level is low only for a particular voice.
    B

    HINT:
    System voice recognition level varies depending on voice and pronunciation. This is not a malfunction.



B
END
A


2. CHECK HARD DISK DRIVE (OPERATION CHECK)

  1. E181026E11
    Enter the "Failure Diagnosis" screen. Refer to Check Hard Disk Drive in Operation Check (Click here).

  1. Select "HDD Check" and check the result.

    OK:
    "OK" is displayed.

    HINT:
    After "HDD Check" is selected, it may take a while until the result is displayed.

Text in Illustration 
*a
Result


NG
REPLACE NAVIGATION RECEIVER ASSEMBLY (Click here)
OK


3. CHECK CABIN
  1. Check that condensation is not likely to occur in the cabin, and that the temperature is not high or extremely low in the cabin.

    HINT:
    1. A humid cabin and a rapid change in temperature may lead to condensation. Condensation in the cabin may cause a short circuit.
    2. The navigation system may not operate normally when the temperature is -20°C (-4°F) or lower, or 65°C (149°F) or higher.

    OK:
    Condensation is not likely being produced and the temperature is not high or extremely low.



NG
SET CABIN TO APPROPRIATE TEMPERATURE
OK


4. CHECK MICROPHONE AND VOICE RECOGNITION (OPERATION CHECK)

  1. E187218E08
    Enter the "Microphone & Voice Recognition Check" screen. Refer to Check Mic & Voice Recognition in Operation Check (Click here).

  1. When voice is input into the microphone, check that the microphone input level meter changes according to the input voice.

  1. Push the recording switch and perform voice recording.

    HINT:
    1. Select the recording switch with the blower motor of the air conditioning system stopped. If an outlet of the air conditioning system is facing the microphone, noise may be recorded.
    2. Voice can be recorded up to 5 seconds.

  1. Check that the recording indicator remains on while recording and that the recorded voice is played normally without noise or distortion.

    OK:
    All check results are normal.

Text in Illustration 
*a
Microphone Input Level Meter
*b
Recording Switch
*c
Stop Switch
*d
Play Switch
*e
Recording Indicator


NG
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
OK

END


← Voice Recognition Difficulty (Jul 2010 – Jun 2012)Voice is not Recognized (Jul 2010 – Jun 2012) →