2007-2013 Highlander Kluger · Service Manual BODY ELECTRICAL

All Doors LOCK/UNLOCK Functions do not Operate Via Master Switch, Driver Side Door Key Cylinder

Circuit diagnosis · Vehicles built Aug 2008 – Jun 2010

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

The main body ECU (instrument panel junction block) receives switch signals from the power window master switch and driver side door key cylinder, and activates the door lock motor on each door according to these signals.

WIRING DIAGRAM

B178838E01
B171370E02

INSPECTION PROCEDURE


1. INSPECT FUSE (DOOR1)
  1. Remove the DOOR1 fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    DOOR1 fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE (DOOR1)
OK


2. CHECK DOOR LOCK OPERATION

Result:
Result
Proceed to
Doors cannot be locked through driver side door key cylinder.
A
Doors cannot be locked through master switch.
B



A
Go to step 6
B


3. READ VALUE USING INTELLIGENT TESTER (DOOR CONTROL SWITCH)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Select Door Lock SW-Lock or Door Lock SW-Unlock in the Data List and read the tester display.

    Main Body (Main Body ECU): 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Door Lock SW-Lock
    Door manual lock switch signal/ON or OFF
    ON: Door control switch on power window regulator master switch is pushed to LOCK
    OFF: Door control switch on power window regulator master switch is not pushed
    -
    Door Lock SW-Unlock
    Door manual unlock switch signal/ON or OFF
    ON: Door control switch on power window regulator master switch is pushed to UNLOCK
    OFF: Door control switch on power window regulator master switch is not pushed
    -

    OK:
    On the tester screen, each item changes between ON and OFF according to the chart above.



NG
Go to step 4
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)

4. INSPECT POWER WINDOW MASTER SWITCH
  1. Remove the power window master switch (Click here).

  1. for LHD:

    1. B164359E13
      Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      Locked
      Below 1 Ω
      1 - 2
      1 - 9
      OFF (Free)
      10 kΩ or higher
      1 - 9
      Unlocked
      Below 1 Ω

  1. for RHD:

    1. B164359E17
      Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      9 - 2
      Locked
      Below 1 Ω
      9 - 2
      9 - 8
      OFF (Free)
      10 kΩ or higher
      9 - 8
      Unlocked
      Below 1 Ω



NG
REPLACE POWER WINDOW MASTER SWITCH (Click here)
OK


5. CHECK HARNESS AND CONNECTOR (POWER WINDOW MASTER SWITCH CIRCUIT)
  1. Disconnect the instrument panel junction block connector.

  1. B171371E01
    for LHD:
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      M1-2 (L) - 1K-15
      Always
      Below 1 Ω
      M1-9 (UL) - 1K-12
      Always
      Below 1 Ω
      M1-1 (E) - Body ground
      Always
      Below 1 Ω
      M1-2 (L) - Body ground
      Always
      10 kΩ or higher
      M1-9 (UL) - Body ground
      Always
      10 kΩ or higher

  1. B171371E02
    for RHD:
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      L1-2 (L) - 1K-15
      Always
      Below 1 Ω
      L1-8 (UL) - 1K-12
      Always
      Below 1 Ω
      L1-9 (E) - Body ground
      Always
      Below 1 Ω
      L1-2 (L) - Body ground
      Always
      10 kΩ or higher
      L1-8 (UL) - Body ground
      Always
      10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)

6. READ VALUE USING INTELLIGENT TESTER (DOOR KEY LINKED LOCK AND UNLOCK SWITCH)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Select Door Key SW-Lock or Door Key SW-Unlock in the Data List and read the tester display.

    Main Body (Main Body ECU): 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Door Key SW-Lock
    Door key linked lock switch signal/ON or OFF
    ON: Driver side door key cylinder is turned to LOCK
    OFF: Driver side door key cylinder is not turned
    -
    Door Key SW-Unlock
    Door key linked unlock switch signal/ON or OFF
    ON: Driver side door key cylinder is turned to UNLOCK
    OFF: Driver side door key cylinder is not turned
    -

    OK:
    On the tester screen, each item changes between ON and OFF according to the chart above.



NG
Go to step 7
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)

7. INSPECT FRONT DOOR LOCK ASSEMBLY (FOR DRIVER SIDE)
  1. Remove the front door lock assembly (for Driver Side) (Click here).

  1. B164389E07
    for LHD:
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      7 - 9
      Locked
      Below 1 Ω
      7 - 9
      7 - 10
      OFF (Free)
      10 kΩ or higher
      7 - 10
      Unlocked
      Below 1 Ω

  1. B178840E01
    for RHD:
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      8 - 6
      Locked
      Below 1 Ω
      8 - 6
      8 - 5
      OFF (Free)
      10 kΩ or higher
      8 - 5
      Unlocked
      Below 1 Ω



NG
REPLACE FRONT DOOR LOCK ASSEMBLY (FOR DRIVER SIDE) (Click here)
OK


8. CHECK HARNESS AND CONNECTOR (DOOR KEY LINKED LOCK UNLOCK SWITCH CIRCUIT)

  1. for LHD:

    1. B178839E01
      Disconnect the instrument panel junction block connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      H6-9 (L) - 1K-16 (L2)
      Always
      Below 1 Ω
      H6-10 (UL) - 1K-7 (UL2)
      Always
      Below 1 Ω
      H6-7 (E) - Body ground
      Always
      Below 1 Ω
      H6-9 (L) - Body ground
      Always
      10 kΩ or higher
      H6-10 (UL) - Body ground
      Always
      10 kΩ or higher

  1. for RHD:

    1. Disconnect the main body ECU (instrument panel junction block) and instrument panel junction block connectors.B171372E03

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      G8-6 (L) - 1K-16
      Always
      Below 1 Ω
      G8-5 (UL) - D7-10 (UL3)
      Always
      Below 1 Ω
      G8-8 (E) - Body ground
      Always
      Below 1 Ω
      G8-6 (L) - Body ground
      Always
      10 kΩ or higher
      G8-5 (UL) - Body ground
      Always
      10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)


← All Doors LOCK/UNLOCK Functions do not Operate Via Master Switch, Driver Side Door Key Cylinder (May 2007 – Jul 2008)All Doors LOCK/UNLOCK Functions do not Operate Via Master Switch, Driver Side Door Key Cylinder (from Jul 2010) →