Connecting terminals TC and CG of the DLC3 causes the system to enter the self-diagnostic mode. If a malfunction is present, DTCs will be output.
HINT:
When a particular warning light remains blinking, a ground short in the wiring of terminal TC of the DLC3 or an internal ground short in the relevant ECU is suspected.
WIRING DIAGRAM
INSPECTION PROCEDURE
1. CHECK HARNESS AND CONNECTOR (TERMINAL TC of DLC3 - ECM)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
D55-28 (TC) - D43-13 (TC)
Always
Below 1 Ω
Reconnect the ECM connector.
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (DLC3 - ECM)
OK
2. CHECK HARNESS AND CONNECTOR (TERMINAL CG of DLC3 - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
D43-4 (CG) - Body ground
Always
Below 1 Ω
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (DLC3 - BODY GROUND)
OK
3. CHECK HARNESS AND CONNECTOR (TERMINAL TC of DLC3 - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
D43-13 (TC) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS, CONNECTOR, OR EACH ECU
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)