Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch
Circuit diagnosis · Vehicles built Aug 2008 – Jun 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
- When the AUTO UP/DOWN does not function, the power window control system may be in fail-safe mode. If the system has not been initialized after replacement of the driver door power window regulator motor, it also results in the same problem.
- NOTICE:
- The power window control system uses a multiplex communication system (LIN). Inspect the communication function by following HOW TO PROCEED WITH TROUBLESHOOTING. Troubleshoot the power window control system after confirming that the communication system is functioning properly.
- When the power window regulator motor assembly (on the driver side) is reinstalled or replaced, the power window control system must be initialized.
- After a door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the AUTO UP function is used. In such cases, the AUTO UP function can be resumed by repeating the following operation at least 5 times:
- Close the power window by fully pulling up the power window switch and holding it in the AUTO UP position.
- Open the power window by fully pushing down the switch.
- The power window control system uses a multiplex communication system (LIN). Inspect the communication function by following HOW TO PROCEED WITH TROUBLESHOOTING. Troubleshoot the power window control system after confirming that the communication system is functioning properly.
- HINT:
- If the pulse sensor built into the power window regulator motor assembly (on the driver side) malfunctions, the power window control system enters fail-safe mode. The remote UP/DOWN and AUTO UP/DOWN functions cannot be operated during fail-safe mode. (However, the power window can be closed by holding the power window switch at the AUTO UP position, and opened manually by pushing down the switch.)
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK DTC |
Check for DTCs.
Connect the intelligent tester to the DLC3.
By following the tester screen display, check whether any DTCs are output.
- Result:
Result
Proceed to
No DTCs output
A
DTCs output
B
|
|
||||
| A | |
| 2. READ VALUE USING INTELLIGENT TESTER (D-DOOR MOTOR) |
Use the Data List to check the function of the power window master switch.
D-Door Motor: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
D P/W Auto Switch
Driver side power window AUTO switch signal / ON or OFF
ON: Driver side power window AUTO switch operates
OFF: Driver side power window AUTO switch does not operate
-
D P/W Up Switch
Driver side power window UP switch signal / ON or OFF
ON: Driver side power window UP switch operates
OFF: Driver side power window UP switch does not operate
-
D P/W Down Switch
Driver side power window DOWN switch signal / ON or OFF
ON: Driver side power window DOWN switch operates
OFF: Driver side power window DOWN switch does not operate
-
- OK:
- ON (switch operates) appears on screen.
|
|
||||
| OK | ||
| ||
| 3. INSPECT POWER WINDOW MASTER SWITCH |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
- for LHD:
Tester Connection
Condition
Specified Condition
8 (U) - 1 (E) - 4 (A)
Auto UP
Below 1 Ω
4 (A) - 5 (D) - 1 (E)
Auto Down
Below 1 Ω
- for RHD:
Tester Connection
Condition
Specified Condition
1 (U) - 9 (E) - 4 (A)
Auto UP
Below 1 Ω
4 (A) - 5 (D) - 9 (E)
Auto Down
Below 1 Ω
|
|
||||
| OK | |
| 4. INSPECT FUSE (DOOR NO. 2) |
Remove the DOOR NO. 2 fuse from the instrument panel junction block.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
DOOR NO. 2
Always
Below 1 Ω
|
|
||||
| OK | |
| 5. CHECK WIRE HARNESS (MASTER SWITCH - REGULATOR MOTOR) |
Disconnect the M1 and H1 connectors (LHD).

Disconnect the L1 and G10 connectors (RHD).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- for LHD:
Tester Connection
Condition
Specified Condition
M1-4 (A) - H1-4 (AUTO)
Always
Below 1 Ω
- for RHD:
Tester Connection
Condition
Specified Condition
L1-4 (A) - G10-4 (AUTO)
Always
Below 1 Ω
|
|
||||
| OK | ||
| ||