2007-2013 Highlander Kluger · Service Manual BODY ELECTRICAL

Operating Light Control Rheostat does not Change Light Brightness

Circuit diagnosis · Vehicles built Aug 2008 – Jun 2010

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

In this circuit the meter CPU receives signals for adjusting illumination on the meter. The meter CPU detects the illumination level selected by the user according to the position of the rheostat knob.

HINT:
  1. This model is equipped with an optitron meter, therefore the meter illuminates even in the daytime.
  2. The meter illumination level can be adjusted by turning the rheostat.
  3. The meter illumination dims when the light control switch is turned to the TAIL or HEAD position at night.
  4. Turning the rheostat knob fully upwards cancels the above dimmer control.


WIRING DIAGRAM

E146930E01

INSPECTION PROCEDURE


1. SYSTEM CHECK
  1. Ignition switch on (IG).

  1. Turn the light control rheostat knob fully upwards.

  1. Turn the light control rheostat knob fully downwards.

  1. Turn the light control rheostat knob fully upwards and turn the light control switch to the TAIL or HEAD position.

  1. Check the meter illumination.


Result:
Result
Proceed to
Meter illumination does not change when operating the light control rheostat knob.
A
Dimmer cancel does not operate (Meter illumination does not dim).
B



B
Go to step 3
A


2. READ VALUE USING INTELLIGENT TESTER (RHEOSTAT)
  1. Connect the intelligent tester to the DLC3.

  1. Ignition switch on (IG).

  1. Turn the tester on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Rheostat value
    Light control rheostat/Min.: 0%, Max.: 100%
    Light control rheostat switch is Dark (0%) → Bright (100%)
    -

    OK:
    The value displayed on the tester gradually changes with the actual rheostat operation.



NG
Go to step 4
OK


3. READ VALUE USING INTELLIGENT TESTER (TAIL CANCEL SW)
  1. Connect the intelligent tester to the DLC3.

  1. Ignition switch on (IG).

  1. Turn the tester on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tail Cancel SW
    Tail cancel switch is/ OFF or ON
    OFF: The light control rheostat knob is not turned fully downwards
    -
    ON: The light control rheostat knob is turned fully upwards
    -

    OK:
    Condition displayed on the tester is the same as the actual rheostat position.



NG
Go to step 6
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)

4. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)

  1. E146929E01
    Disconnect the E1 and D3 connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E1-4 (SW1) - D3-7 (T)
    Always
    Below 1 Ω
    E1-24 (SW2) - D3-3 (RV)
    Always
    Below 1 Ω
    E1-39 (SW3) - D3-1 (E)
    Always
    Below 1 Ω
    D3-1 (E) - Body ground
    Always
    10 kΩ or higher
    D3-3 (RV) - Body ground
    Always
    10 kΩ or higher
    D3-7 (T) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. INSPECT LIGHT CONTROL RHEOSTAT

  1. E152419E01
    Remove the light control rheostat with the connector still connected.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D3-1 (E) - D3-3 (RV)
    Turn the light control rheostat knob fully upwards
    8 kΩ or higher
    D3-1 (E) - D3-3 (RV)
    Rheostat knob position is between MIN. and MAX.
    The value changes gradually
    (Between 1 Ω and 8 kΩ)
    D3-1 (E) - D3-3 (RV)
    Turn the light control rheostat knob fully downwards
    Below 1 Ω



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)

6. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)

  1. E146929E04
    Disconnect the E1 and D3 connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D3-5 (TC) - E1-23 (TC)
    Always
    Below 1 Ω
    D3-7 (T) - E1-4 (SW1)
    Always
    Below 1 Ω
    D3-5 (TC) - Body ground
    Always
    10 kΩ or higher
    D3-7 (T) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7. INSPECT LIGHT CONTROL RHEOSTAT

  1. E152419E02
    Remove the light control rheostat with the connector still connected.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D3-5 (TC) - D3-7 (T)
    Turn the light control rheostat knob fully downwards
    Below 1 Ω
    D3-5 (TC) - D3-7 (T)
    Turn the light control rheostat knob fully upwards (Tail cancel ON)
    8 kΩ or higher



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)


← Operating Light Control Rheostat does not Change Light Brightness (May 2007 – Jul 2008)Operating Light Control Rheostat does not Change Light Brightness (from Jul 2010) →