P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built May 2007 – Jul 2008
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the duty cycle of the SLT solenoid valve to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.(*): Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then
Duty Ratio=A/(A + B) x 100(%)
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2716 |
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic). |
|


MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SLT) |
Disconnect the transmission wire connector from the transaxle.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
2 (SLT+) - 8 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
2 (SLT+) - Body ground
Always
10 kΩ or higher
8 (SLT-) - Body ground
Always
↑
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transaxle.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
B2-13 (SLT+) - B2-12 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
B2-13 (SLT+) - Body ground
Always
10 kΩ or higher
B2-12 (SLT-) - Body ground
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE (SLT) |
Remove the shift solenoid valve SLT.

Measure the resistance according to the value(s) in the table below.
- Standard resistance :
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||