P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)
Diagnostic trouble codes · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0778 |
ECM checks for an open or short circuit in shift solenoid valves SL2 (1-trip detection logic) Hybrid IC for solenoid indicates fail. |
|
MONITOR DESCRIPTION
The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL, and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.) (Click here).WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SL2) |
Disconnect the transmission wire connector from the transaxle.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
5 (SL2+) - 12 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
5 (SL2+) - Body ground
Always
10 kΩ or higher
12 (SL2-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transaxle.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
B49-31 (SL2+) - B48-34 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
B49-31 (SL2+) - Body ground
Always
10 kΩ or higher
B48-34 (SL2-) - Body ground
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE (SL2) |
Remove the shift solenoid valve SL2.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||
