Measure the voltage according to the value(s) in the table below.
Standard voltage:
LH Side:
Tester Connection
Condition
Specified Condition
Q8-1 - Q8-2
Visor raise
Below 1 V
Visor lower and mirror cover open
11 to 14 V
Visor lower and mirror cover close
Below 1 V
RH Side:
Tester Connection
Condition
Specified Condition
Q6-1 - Q6-2
Visor raise
Below 1 V
Visor lower and mirror cover open
11 to 14 V
Visor lower and mirror cover close
Below 1 V
If the result is not as specified, there is a malfunction on the wire harness side. If the result is as specified, but the vanity light does not come on, replace the bulb.