B1412/12 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Aug 2008 – Jun 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1412/12 |
Open or short in ambient temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AMBI TEMP SENS) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent teste main switch on.
Select the item below in the Data List, and read the value displayed on the intelligent teste.
Data List / Air Conditioner: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambi Temp Sens
Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.94°C (150.71°F)
Actual ambient temperature is displayed
Open circuit: -23.3°C (-9.94°F)
Short circuit: 65.94°C (150.71°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from PROBLEM SYMPTOMS TABLE)
B
OK (Checking from DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT AMBIENT TEMPERATURE SENSOR |
Remove the ambient temperature sensor (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A7-1 - A7-2
10°C (50°F)
3.00 to 3.73 kΩ
A7-1 - A7-2
15°C (50°F)
2.45 to 2.88 kΩ
A7-1 - A7-2
20°C (68°F)
1.95 to 2.30 kΩ
A7-1 - A7-2
25°C (77°F)
1.60 to 1.80 kΩ
A7-1 - A7-2
30°C (86°F)
1.28 to 1.47 kΩ
A7-1 - A7-2
35°C (95°F)
1.00 to 1.22 kΩ
A7-1 - A7-2
40°C (104°F)
0.80 to 1.00 kΩ
A7-1 - A7-2
45°C (113°F)
0.65 to 0.85 kΩ
A7-1 - A7-2
50°C (122°F)
0.50 to 0.70 kΩ
A7-1 - A7-2
55°C (131°F)
0.44 to 0.60 kΩ
A7-1 - A7-2
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the A7 sensor connector.

Disconnect the D33 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A7-1 - D33-5 (TAM)
Always
Below 1 Ω
A7-2 - D33-13 (SG-2)
Always
Below 1 Ω
D33-5 (TAM) - Body ground
Always
10 kΩ or higher
D33-13 (SG-2) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||