2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1412/12 Ambient Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built May 2007 – Jul 2008

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
DTC No.
DTC Detection Condition
Trouble Area
B1412/12
Open or short in ambient temperature sensor circuit
  1. Ambient temperature sensor
  2. Wire harness between ambient temperature sensor and Air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM

E127563E04

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (AMBI TEMP SENS)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent teste main switch on.

  1. Select the item below in the Data List, and read the value displayed on the intelligent teste.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambi Temp Sens
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.94°C (150.71°F)
    Actual ambient temperature is displayed
    Open circuit: -23.3°C (-9.94°F)
    Short circuit: 65.94°C (150.71°F)

    OK:
    The display is as specified in the normal condition column.


    Result:
    Result
    Proceed to
    NG
    A
    OK (Checking from PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2. INSPECT AMBIENT TEMPERATURE SENSOR

  1. E114516E16
    Remove the ambient temperature sensor (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A7-1 - A7-2
    10°C (50°F)
    3.00 to 3.73 kΩ
    A7-1 - A7-2
    15°C (50°F)
    2.45 to 2.88 kΩ
    A7-1 - A7-2
    20°C (68°F)
    1.95 to 2.30 kΩ
    A7-1 - A7-2
    25°C (77°F)
    1.60 to 1.80 kΩ
    A7-1 - A7-2
    30°C (86°F)
    1.28 to 1.47 kΩ
    A7-1 - A7-2
    35°C (95°F)
    1.00 to 1.22 kΩ
    A7-1 - A7-2
    40°C (104°F)
    0.80 to 1.00 kΩ
    A7-1 - A7-2
    45°C (113°F)
    0.65 to 0.85 kΩ
    A7-1 - A7-2
    50°C (122°F)
    0.50 to 0.70 kΩ
    A7-1 - A7-2
    55°C (131°F)
    0.44 to 0.60 kΩ
    A7-1 - A7-2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE AMBIENT TEMPERATURE SENSOR (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

  1. E152697E03
    Disconnect the A7 sensor connector.

  1. Disconnect the D33 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A7-1 - D33-5 (TAM)
    Always
    Below 1 Ω
    A7-2 - D33-13 (SG-2)
    Always
    Below 1 Ω
    D33-5 (TAM) - Body ground
    Always
    10 kΩ or higher
    D33-13 (SG-2) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)


← B1411/11 Room Temperature Sensor Circuit (from Jul 2010)B1412/12 Ambient Temperature Sensor Circuit (Aug 2008 – Jun 2010) →