2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

Blower Motor Circuit

Circuit diagnosis · Vehicles built May 2007 – Jul 2008

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

The blower motor is operated by signals from the air conditioning amplifier. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.
E115031E06

WIRING DIAGRAM

E123559E07

INSPECTION PROCEDURE


1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (BLOWER MOTOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Active Test, and then check that the blower motor operates.

    Active Test / Air Conditioner:  
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -

    Result:
    Result
    Proceed to
    NG (blower motor does not operate)
    A
    NG (blower motor operates but does not change speed)
    B
    OK
    C



B
Go to step 5

C
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
A


2. INSPECT FUSE (HTR-H)
  1. Remove the HTR H-fuse from the main body ECU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    HTR H-fuse
    Always
    Below 1Ω



NG
REPLACE FUSE
OK


3. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)

  1. E115959E19
    Disconnect the D30 motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D30-1 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY)

  1. E115959E20
    Disconnect the D30 motor connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D30-3 (+B) - Body ground
    Ignition switch on (IG)
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)

  1. E143742E93
    Disconnect the D33 amplifier connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D33-23 (BLW) - D33-14 (GND)
    Ignition switch on (IG)
    Blower switch OFF
    4.5 to 5.5 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6. CHECK AIR CONDITIONING AMPLIFIER

  1. E127572E04
    Remove the air conditioning amplifier with its connectors still connected.

  1. Check the waveform of the amplifier connector.

    OK:
    Waveform is as shown in the illustration.

    HINT:
    The waveform varies with the blower level.

    Item
    Content
    Tester Connection
    D33-23 (BLW) - D33-14 (GND)
    Tool Setting
    1 V/DIV., 500 μsec./DIV.
    Condition
    Ignition switch on (IG)
    Blower switch LO



NG
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
OK

REPLACE BLOWER W/ FAN MOTOR SUB-ASSEMBLY (Click here)


← B1499/99 Multiplex Communication Circuit (from Jul 2012)Blower Motor Circuit (Aug 2008 – Jun 2010) →