B1835/58 Short in Curtain Shield Squib LH Circuit
Diagnostic trouble codes · Vehicles built from Jul 2010
Also covers:
- B1836/58 Open in Curtain Shield Squib LH Circuit
- B1837/58 Short to GND in Curtain Shield Squib LH Circuit
- B1838/58 Short to B+ in Curtain Shield Squib LH Circuit
DESCRIPTION
The curtain shield squib LH circuit consists of the center airbag sensor assembly and curtain shield airbag assembly LH.The center airbag sensor assembly uses this circuit to deploy the airbag when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib LH circuit.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1835/58 |
|
|
| B1836/58 |
|
|
| B1837/58 |
|
|
| B1838/58 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Perform the simulation method by selecting check mode (Signal Check) using the intelligent tester (Click here).
- After selecting check mode (Signal Check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).
- Perform the simulation method by selecting check mode (Signal Check) using the intelligent tester (Click here).
| 1. CHECK CONNECTORS |
Turn the ignition switch off.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the curtain shield airbag assembly LH and center airbag sensor assembly.
- OK:
- The connectors are properly connected.
- HINT:
- If the connectors are not connected securely, reconnect the connectors and proceed to the next inspection.
Disconnect the connectors from the curtain shield airbag assembly LH and center airbag sensor assembly.
Check that the terminals of the connectors are not damaged.
- OK:
- The terminals are not deformed or damaged.
Check that the No. 2 floor wire connector (on the curtain shield airbag assembly LH side) is not damaged.
- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
Check that the short spring for the No. 2 floor wire with the activation prevention mechanism is not deformed or damaged.
- OK:
- The short spring is not deformed or damaged.
|
|
||||
| OK | |
| 2. CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (CURTAIN SHIELD SQUIB LH) |
Connect the connector to the center airbag sensor assembly.

Connect SST (resistance 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag assembly LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting.
- SST
- 09843-18061
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1835, B1836, B1837, B1838 or 58 is not output.
- HINT:
- Codes other than DTCs B1835, B1836, B1837, B1838 and 58 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 3. CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD SQUIB LH CIRCUIT) |
Turn the ignition switch off.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Disconnect the No. 2 floor wire from the center airbag sensor assembly.
Check for a short to B+ in the circuit.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
O11-1 (ICL+) - Body ground
Ignition switch on (IG)
Below 1 V
O11-2 (ICL-) - Body ground
Ignition switch on (IG)
Below 1 V
Check for an open in the circuit.
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
O11-1 (ICL+) - O11-2 (ICL-)
Always
Below 1 Ω
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
O11-1 (ICL+) - Body ground
Always
1 MΩ or higher
O11-2 (ICL-) - Body ground
Always
1 MΩ or higher
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
O11-1 (ICL+) - O11-2 (ICL-)
Always
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
Restore the released activation prevention mechanism of connector B to the original condition.

Connect the connectors to the curtain shield airbag assembly LH and center airbag sensor assembly.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1835, B1836, B1837, B1838 or 58 is not output.
- HINT:
- Codes other than DTCs B1835, B1836, B1837, B1838 and 58 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||