Security Indicator Light Circuit
Circuit diagnosis · Vehicles built May 2007 – Jul 2008
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
Even when the theft deterrent system is in the disarmed state, the security indicator light blinks due to a signal output from the immobiliser system. The security indicator light blinks continuously due to a continuous signal received from the immobiliser system while in the armed state.The certification ECU (smart key ECU assembly) causes the security indicator light to come on or blink only during the arming preparation and alarm sounding states.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester main switch on.
Select the item below in the Active Test and then check that the indicator operates.
Entry&Start: Tester Display
Test Part
Control Range
Diagnostic Note
Security Indicator
Security indicator light
ON / OFF
-
- OK:
- The security indicator light blinks or goes off correctly when operating it through the intelligent tester.
|
|
||||
| OK | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT - CERTIFICATION ECU) |
Disconnect the D36 ECU connector.

Disconnect the E13 connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
D36-2 (IND) - E13-2 (LP)
Always
Below 1 Ω
D36-2 (IND) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT - BODY GROUND) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
E13-5 (E) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 4. INSPECT SECURITY INDICATOR LIGHT |
Reconnect the E13 connector with the D36 ECU connector still disconnected.

Apply battery voltage from the wire harness back side between the specified terminals of the indicator, and check the lighting condition of the security indicator light.
- Standard :
Measurement Condition
Specified Condition
Battery positive (+) → Terminal E13-2 (IND+)
Battery negative (-) → Terminal E13-5 (E)
Security indicator light comes on
- NOTICE:
- If the positive (+) lead and the negative (-) lead are incorrectly connected, the security indicator light will not come on.
- Voltage of more than 12 V will damage the security indicator light.
- If the voltage is too low, the security indicator light will not come on.
- If the positive (+) lead and the negative (-) lead are incorrectly connected, the security indicator light will not come on.
|
|
||||
| OK | ||
| ||