2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT EVAPORATOR TEMPERATURE SENSOR

  1. Measure the resistance according to the value(s) in the table below.

    E154273E01

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    1 - 2
    -5°C (23°F)
    5.65 to 6.95 kΩ
    1 - 2
    0°C (32°F)
    4.40 to 5.35 kΩ
    1 - 2
    5°C (41°F)
    3.40 to 4.15 kΩ
    1 - 2
    10°C (50°F)
    2.70 to 3.25 kΩ
    1 - 2
    15°C (59°F)
    2.14 to 2.58 kΩ
    1 - 2
    20°C (68°F)
    1.71 to 2.05 kΩ
    1 - 2
    25°C (77°F)
    1.38 to 1.64 kΩ
    1 - 2
    30°C (86°F)
    1.11 to 1.32 kΩ

    If the resistance is not as specified, replace the evaporator temperature sensor.

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).