P0010 Camshaft Position "A" Actuator Circuit (Bank 1)
Diagnostic trouble codes · Vehicles built May 2007 – Jun 2010
Also covers:
- P0020 Camshaft Position "A" Actuator Circuit (Bank 2)
Versions by build date: May 2007 – Jun 2010 from Jul 2010
DESCRIPTION
- HINT:
- These DTCs relate to the oil control valve for intake camshaft.
The ECM controls the oil control valve, based on the signals transmitted by several sensors. The variable valve timing controller regulates the intake camshaft angle using oil pressure through the oil control valve. As a result, the relative positions of the camshaft and crankshaft are optimized, the engine torque and fuel economy improve, and the exhaust emissions decrease under overall driving conditions. The ECM detects the actual intake valve timing using signals from the camshaft and crankshaft position sensors, and performs feedback control. This is how the target intake valve timing is verified by the ECM.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0010 |
Open or short in oil control valve circuit (1 trip detection logic) |
|
| P0020 |
Open or short in oil control valve circuit (1 trip detection logic) |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- If DTC P0010 is displayed, check the bank 1 VVT system circuit.
- Bank 1 refers to the bank that includes cylinder No. 1.
- If DTC P0020 is displayed, check the bank 2 VVT system circuit.
- Bank 2 refers to the bank that does not include cylinder No. 1.
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
- If DTC P0010 is displayed, check the bank 1 VVT system circuit.
| 1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (OPERATE OIL CONTROL VALVE) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester on.
Warm up the engine and idle it.
Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Control the VVT system (Bank 1) or Control the VVT System (Bank 2).
Check the engine speed while operating the oil control valve using the tester.
- OK:
Tester Operation
Specified Condition
Oil control valve OFF
Normal engine idle speed
Oil control valve ON
Engine idles roughly or stalls (soon after oil control valve switched from OFF to ON)
|
|
||||
| OK | ||
| ||
| 2. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (FOR INTAKE CAMSHAFT) |
Disconnect the intake camshaft timing oil control valve connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
6.9 to 7.9 Ω
Reconnect the oil control valve connector.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (OIL CONTROL VALVE - ECM) |
Disconnect the intake camshaft timing oil control valve connector.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for open):
- Bank 1:
Tester Connection
Condition
Specified Condition
B3-17 (OC1+) - B24-1
Always
Below 1 Ω
B3-16 (OC1-) - B24-2
Always
Below 1 Ω
- Bank 2:
Tester Connection
Condition
Specified Condition
B3-15 (OC2+) - B25-1
Always
Below 1 Ω
B3-14 (OC2-) - B25-2
Always
Below 1 Ω
- Standard resistance (Check for short):
- Bank 1:
Tester Connection
Condition
Specified Condition
B3-17 (OC1+) or B24-1 - Body ground
Always
10 kΩ or higher
B3-16 (OC1-) or B24-2 - Body ground
Always
10 kΩ or higher
- Bank 2:
Tester Connection
Condition
Specified Condition
B3-15 (OC2+) or B25-1 - Body ground
Always
10 kΩ or higher
B3-14 (OC2-) or B25-2 - Body ground
Always
10 kΩ or higher
Reconnect the oil control valve connector.
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||